Less repetitive checking.More review capacity.
Apply repeatable standards checks across PDF drawing binders, then review the findings with the evidence beside them. Built to reduce the searching and comparison work that slows infrastructure drawing delivery.
Coversheets. Title blocks. Deltas and clouding. A working platform for designers, utilities and client QA teams.
Platform walkthrough
Watch the platform
run a binder.
See the application in operation, from drawing intake to the report and annotated evidence. This is the running-platform video from the existing Validation page.
This earlier recording includes legacy features. Support-package export is disabled in the current evaluation build.
A more useful review starting point
From a drawing binder
to a finding you can follow.
Manual standards review means repeated searching, comparing, and documenting. SVS organizes supported checks and their evidence so the next correction is easier to investigate.
Start with the right context.
Select the PDF binder, supported client profile, and issue stage. Confirm that the intended review task falls within the implemented checks.
See findings in context.
Review the client report, technical detail, and annotated drawing evidence. Processing completion and drawing results are reported separately.
Keep the designer in control.
Resolve the finding in the normal drafting workflow, export the revised PDF, and run the applicable checks again. The client decides acceptance.
Supported check families
The details that
hold a package together.
Client requirements establish the target. Implemented checks examine supported PDF content, record the result, and retain the basis for review.
Coversheets & title blocks
Check supported drawing identifiers, descriptions, dates, WBS fields, revisions, and issue requirements. Carry sheet context into the report.
Clouds, deltas & relationships
Inspect supported color, size, lineweight, orientation, and relationship conditions. Selected native cloud groups also receive bounded contact and configured-color measurements.
Reports & annotated evidence
Follow a finding through the client workbook, technical detail, and drawing evidence. Keep unresolved checks visible alongside the completed results.
Coverage is defined by the implemented rule, profile, and PDF representation. A pilot confirms which client requirements are covered and which still need separate review.
A report you can interrogate
Know what was checked.
Know what still needs you.
A completed run and a passing drawing are different things. SVS makes that distinction visible before the team relies on the report.
Criterion met
The supported check met its configured criterion.
Mismatch found
Review the finding and confirm the client rule applies.
Attention required
Evidence, measurement, or applicability remains unresolved.
Processing unfinished
A required stage or evidence control did not finish satisfactorily.
Evidence that belongs to this run.
Separate input snapshots, run folders, and result-to-evidence checks connect the report to the material actually processed. Annotated output follows the final findings.
Configured operational dispositions remain separate from strict findings. The client’s authorized reviewer determines acceptance; a software status does not authorize release.
Real binder. Actual client report.
Go beyond the screenshot.
Review the workbook.
Explore the supplied Taliesin demonstration report sheet by sheet. Search the findings, inspect every column and open the embedded evidence previews.
All workbook sheets are included except Run Integrity and Advisory – Design Review. Summary totals and the other sheets retain their original contents. These are reported findings from the supplied run, not independently confirmed defect counts.
11 included workbook sheets. Scroll within a sheet to review every column.
Executive Summary
27 worksheet rows · 8 columns
| 1 | STANDARD VALIDATION SYSTEMS CORP | |||||||
|---|---|---|---|---|---|---|---|---|
| 2 | Client Validation Report · Clean workbook view | |||||||
| 3 | ENGINE CHECKS COMPLETE — Review findings; engineering approval is still required. | |||||||
| 4 | ||||||||
| 5 | Observed Findings | FAIL | Profile | Operational_Accepted | ||||
| 6 | Pages Reviewed | 38 | Pages Failed | 37 | ||||
| 7 | Actionable Issues | 237 | Accepted by Operational | 164 | ||||
| 8 | Advisory / Design Review | 70 | Evidence Binding | PASS | ||||
| 9 | Strict Reference Findings | 401 | Hard-Touch Failures | 43 | ||||
| 10 | Title Block Pages Passed | 28 / 38 | Coversheet | PASS | ||||
| 11 | Source Time Span | 3m 29s | Last Source Update | 2026-09-14 17:59:00 | ||||
| 12 | ||||||||
| 13 | Primary Failure Summary | |||||||
| 14 | Delta lineweight out of standard (55); Delta size out of standard (34); Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag (34); Red/green connector color is incorrect (23); Delta has no measured revision cloud. Boxed-note, construction-note, delta-anchor, leader, and callout context do not satisfy the hard cloud-touch rule. (10); Green hatch spacing out of standard (9); Title-block current REV does not match the current WBS revision row (8); Delta letter/number missing or unreadable (8) | |||||||
| 15 | ||||||||
| 16 | ||||||||
| 17 | ||||||||
| 18 | ||||||||
| 19 | ||||||||
| 20 | ||||||||
| 21 | Report Navigation | |||||||
| 22 | Actionable Issues | Correction-required items using the selected operational profile. | ||||||
| 23 | Accepted by Operational | Strict-reference findings accepted by the selected operational profile. | ||||||
| 24 | Advisory – Design Review | Operationally accepted or standards-review conditions that still require reviewer awareness. | ||||||
| 25 | Visual Evidence | Issue-level zoomed preview images, evidence paths, and annotated PDF references. | ||||||
| 26 | Title Block Review | Full page-level title block extraction and validation output. | ||||||
| 27 | Coversheet Review | Coversheet pass/fail checklist and extracted project metadata. | ||||||
Actionable Issues
241 worksheet rows · 12 columns
| 1 | Actionable Issues | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Correction-required items from the selected operational result. Internal patch/debug fields are intentionally hidden from this client view. | |||||||||||
| 3 | ||||||||||||
| 4 | Page | Object ID | Severity | Result | Action | Check Area | Check | Reason | Observed | Expected | Evidence | Annotated PDF |
| 5 | 1 | 0238-000.002S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=1.0; matched_wbs_rev=2A; sheet_rev=2A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 6 | 2 | 0238-000.002S02-1 | High | FAIL | Correction Required | Title Block | PE stamp present on every IFC binder page | Required PE stamp is missing or could not be verified on this IFC binder page. | required=YES; present=FAIL; family=INDEX; method=MULTI_PROBE_RING_TEXT_V9; zone=FLOATING_BOM_APPROVAL | A verifiable PE stamp is required on every page of an IFC binder. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 7 | 3 | 0238-000.002S02-2 | High | FAIL | Correction Required | Title Block | PE stamp present on every IFC binder page | Required PE stamp is missing or could not be verified on this IFC binder page. | required=YES; present=FAIL; family=INDEX; method=MULTI_PROBE_RING_TEXT_V9; zone=FLOATING_BOM_APPROVAL | A verifiable PE stamp is required on every page of an IFC binder. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 8 | 5 | 0238-003.002S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 9 | 5 | P005_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 10 | 5 | P005_G003 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 11 | 5 | P005_G004 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 12 | 5 | P005_G005 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 13 | 5 | P005_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-003.002S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 14 | 6 | 0238-005.004S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 15 | 6 | P006_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.587 pt. Touch tolerance: 0.05 pt. | gap_pt=0.587; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; same_color_connector_or_leader; comp_delta_groups=P006_G004|P006_G003|P006_G002|P006_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.587 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 16 | 6 | P006_G005 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 17 | 6 | P006_G005_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8321 in; height=0.7206 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 18 | 6 | P006_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.004S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 19 | 7 | 0238-005.004S01-R | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=7.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 20 | 7 | P007_G003 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 1.272 pt. Touch tolerance: 0.05 pt. | gap_pt=1.272; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P007_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=1.272 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 21 | 7 | P007_G004 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 22 | 7 | P007_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8157 in; height=0.7064 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 23 | 7 | P007_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0238-005.004S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.4123; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 24 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Title block asset name and asset code present | Required title-block asset name or asset code is missing or unreadable. | Observed asset: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 25 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Sheet title present | Sheet title present | Observed title: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 26 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Sheet description present | Sheet description present | Observed description: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 27 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Internal-information text present | Internal-information text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 28 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Title block logo present | Required title-block logo was not detected in the logo cell. | tb_logo_ok=FAIL | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 29 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=; matched_wbs_rev=3A; sheet_rev=3A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 30 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Right-panel current REV present | Right-panel current REV present | Observed sheet_rev: 3A | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 31 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Scale present | Scale present | Observed scale: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 32 | 8 | 0238-005.005S01 | High | FAIL | Correction Required | Title Block | Safety warning text present | Safety warning text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 33 | 8 | P008_G002 | Medium | FAIL | Correction Required | Green Removal Hatching | Green removal hatch integrity outside standard | Green removal cloud is missing required hatch evidence. Missing hatch count: 13. | observed_member_count=10; observed_hatch_count=6; observed_visible_line_count=5; observed_measured_line_count=5; missing=13 | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 34 | 8 | P008_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.005S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 35 | 9 | P009_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.681 pt. Touch tolerance: 0.05 pt. | gap_pt=0.681; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P009_G001|P009_G006; old_touch=PASS; old_corr=PASS; old_gap_pt=0.681 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 36 | 9 | P009_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 37 | 9 | P009_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.514 pt. Touch tolerance: 0.05 pt. | gap_pt=0.514; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P009_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.514 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 38 | 9 | P009_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2972 in; height=1.1234 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 39 | 9 | P009_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 40 | 9 | P009_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 41 | 9 | P009_G005 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 42 | 9 | P009_G005_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 43 | 9 | P009_G006 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 44 | 9 | P009_G006_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 45 | 9 | P009_G007 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 46 | 9 | P009_G007_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 47 | 9 | P009_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.020S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 48 | 10 | P010_G001 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6251 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 49 | 10 | P010_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2701 in; height=1.1 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 50 | 10 | P010_G002 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6249 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 51 | 10 | P010_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2701 in; height=1.1 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 52 | 10 | P010_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.021S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 53 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Title block asset name and asset code present | Required title-block asset name or asset code is missing or unreadable. | Observed asset: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 54 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Sheet title present | Sheet title present | Observed title: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 55 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Sheet description present | Sheet description present | Observed description: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 56 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Internal-information text present | Internal-information text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 57 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Title block logo present | Required title-block logo was not detected in the logo cell. | tb_logo_ok=FAIL | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 58 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=; matched_wbs_rev=7A; sheet_rev=7A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 59 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Right-panel current REV present | Right-panel current REV present | Observed sheet_rev: 7A | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 60 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Scale present | Scale present | Observed scale: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 61 | 11 | 0238-008.010S01 | High | FAIL | Correction Required | Title Block | Safety warning text present | Safety warning text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 62 | 11 | P011_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.010S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 63 | 12 | P012_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.012S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.5397; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 64 | 13 | 0238-008.012S02 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=1.0; matched_wbs_rev=2A; sheet_rev=2A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 65 | 13 | P013_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.421 pt. Touch tolerance: 0.05 pt. | gap_pt=0.421; tolerance_pt=0.05; delta_count=1; cloud_path_count=5; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P013_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.421 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 66 | 13 | P013_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.012S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 67 | 14 | P014_G001 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 68 | 14 | P014_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 69 | 14 | P014_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.016S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 70 | 15 | P015_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 48.323 pt. Touch tolerance: 0.05 pt. | gap_pt=48.323; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P015_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=48.323 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 71 | 15 | P015_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.032S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 72 | 16 | 0238-008.033S01 | High | FAIL | Correction Required | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=7A; sheet_rev=7A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |
| 73 | 16 | P016_G003 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.136 pt. Touch tolerance: 0.05 pt. | gap_pt=0.136; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P016_G003|P016_G004; comp_delta_groups=P016_G004|P016_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.136 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 74 | 16 | P016_G003 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 75 | 16 | P016_G004 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.149 pt. Touch tolerance: 0.05 pt. | gap_pt=0.149; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P016_G003|P016_G004; comp_delta_groups=P016_G004|P016_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.149 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 76 | 16 | P016_G004 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 77 | 16 | P016_G013 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta/cloud edge gap could not be measured, so required physical touch could not be proven. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; same_color_connector_or_leader; comp_delta_groups=P016_G014; old_touch=PASS; old_corr=PASS; old_gap_pt= | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 78 | 16 | P016_G016 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.073 pt. Touch tolerance: 0.05 pt. | gap_pt=0.073; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P016_G016; old_touch=PASS; old_corr=PASS; old_gap_pt=0.073 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 79 | 16 | P016_G018 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.169 pt. Touch tolerance: 0.05 pt. | gap_pt=0.169; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P016_G018; old_touch=PASS; old_corr=PASS; old_gap_pt=0.169 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 80 | 16 | P016_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.033S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 81 | 17 | P017_G001 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 82 | 17 | P017_G001_D02 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.2084 in; height=0.1805 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 83 | 17 | P017_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-008.051S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 84 | 18 | P018_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8267 in; height=0.7159 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 85 | 18 | P018_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 86 | 18 | P018_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7294 in; height=0.6317 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 87 | 18 | P018_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.053S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0983; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 88 | 19 | P019_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6109 in; height=0.5291 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 89 | 19 | P019_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 90 | 19 | P019_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7432 in; height=0.6437 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 91 | 19 | P019_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0238-008.053S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.7026; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 92 | 20 | P020_G001 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 93 | 20 | P020_G002 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 94 | 20 | P020_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 95 | 20 | P020_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.054S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 96 | 21 | P021_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.055S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 97 | 22 | P022_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.055S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.2024; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 98 | 23 | P023_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7476 in; height=0.6474 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 99 | 23 | P023_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.282 pt. Touch tolerance: 0.05 pt. | gap_pt=0.282; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P023_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.282 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 100 | 23 | P023_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7476 in; height=0.6474 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 101 | 23 | P023_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.056S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 102 | 24 | P024_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.057S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.3035; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 103 | 25 | P025_G021 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 104 | 25 | P025_G021_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7544 in; height=0.6534 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 105 | 25 | P025_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.063S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 106 | 26 | P026_G001 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.9998 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 107 | 26 | P026_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6741 in; height=0.5838 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 108 | 26 | P026_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 109 | 26 | P026_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 110 | 26 | P026_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7543 in; height=0.6532 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 111 | 26 | P026_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 112 | 26 | P026_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0283-008.063S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0727; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 113 | 27 | P027_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.1281 in; height=0.977 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 114 | 27 | P027_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 115 | 27 | P027_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.1281 in; height=0.977 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 116 | 27 | P027_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.070S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 117 | 28 | P028_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 118 | 28 | P028_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7535 in; height=0.6525 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 119 | 28 | P028_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 120 | 28 | P028_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 121 | 28 | P028_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7535 in; height=0.6525 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 122 | 28 | P028_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.070S02-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.7026; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 123 | 29 | P029_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 124 | 29 | P029_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 125 | 29 | P029_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 126 | 29 | P029_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 127 | 29 | P029_G005_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 128 | 29 | P029_G006_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 129 | 29 | P029_G007 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.265 pt. Touch tolerance: 0.05 pt. | gap_pt=0.265; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G007; old_touch=PASS; old_corr=PASS; old_gap_pt=0.265 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 130 | 29 | P029_G007_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 131 | 29 | P029_G008 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.165 pt. Touch tolerance: 0.05 pt. | gap_pt=0.165; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G008; old_touch=PASS; old_corr=PASS; old_gap_pt=0.165 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 132 | 29 | P029_G008_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 133 | 29 | P029_G009_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 134 | 29 | P029_G010_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 135 | 29 | P029_G011_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 136 | 29 | P029_G012_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 137 | 29 | P029_G013_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 138 | 29 | P029_G014 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.261 pt. Touch tolerance: 0.05 pt. | gap_pt=0.261; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G014; old_touch=PASS; old_corr=PASS; old_gap_pt=0.261 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 139 | 29 | P029_G014_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 140 | 29 | P029_G015_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 141 | 29 | P029_G016 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 142 | 29 | P029_G016_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 143 | 29 | P029_G016_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7474 in; height=0.6472 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 144 | 29 | P029_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 145 | 30 | P030_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 146 | 30 | P030_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 1.017 pt. Touch tolerance: 0.05 pt. | gap_pt=1.017; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=1.017 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 147 | 30 | P030_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 148 | 30 | P030_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 149 | 30 | P030_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 150 | 30 | P030_G005_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 151 | 30 | P030_G006_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 152 | 30 | P030_G007_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 153 | 30 | P030_G008_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 154 | 30 | P030_G009_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 155 | 30 | P030_G010_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 156 | 30 | P030_G011_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 157 | 30 | P030_G012 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.061 pt. Touch tolerance: 0.05 pt. | gap_pt=0.061; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G012; old_touch=PASS; old_corr=PASS; old_gap_pt=0.061 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 158 | 30 | P030_G012_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 159 | 30 | P030_G013_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 160 | 30 | P030_G014_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 161 | 30 | P030_G015 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.864 pt. Touch tolerance: 0.05 pt. | gap_pt=0.864; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G015; old_touch=PASS; old_corr=PASS; old_gap_pt=0.864 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 162 | 30 | P030_G015_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 163 | 30 | P030_G016_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 164 | 30 | P030_G017_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 165 | 30 | P030_G018_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 166 | 30 | P030_G019 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.371 pt. Touch tolerance: 0.05 pt. | gap_pt=0.371; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G019; old_touch=PASS; old_corr=PASS; old_gap_pt=0.371 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 167 | 30 | P030_G019_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 168 | 30 | P030_G020_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 169 | 30 | P030_G021_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 170 | 30 | P030_G022_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 171 | 30 | P030_G023_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 172 | 30 | P030_G024_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 173 | 30 | P030_G025_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 174 | 30 | P030_G026_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 175 | 30 | P030_G027_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 176 | 30 | P030_G028_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 177 | 30 | P030_G029 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 178 | 30 | P030_G029_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 179 | 30 | P030_G029_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.675 in; height=0.5846 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 180 | 30 | P030_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.8025; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 181 | 31 | P031_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.503 pt. Touch tolerance: 0.05 pt. | gap_pt=0.503; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P031_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.503 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 182 | 31 | P031_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 183 | 31 | P031_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 184 | 31 | P031_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.334 pt. Touch tolerance: 0.05 pt. | gap_pt=0.334; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P031_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.334 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 185 | 31 | P031_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 186 | 31 | P031_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 187 | 31 | P031_G003 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 188 | 31 | P031_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 189 | 31 | P031_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 190 | 31 | P031_G004 | Medium | FAIL | Correction Required | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 191 | 31 | P031_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 192 | 31 | P031_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 193 | 31 | P031_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 194 | 32 | P032_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 195 | 32 | P032_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 196 | 32 | P032_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.307 pt. Touch tolerance: 0.05 pt. | gap_pt=0.307; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P032_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.307 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 197 | 32 | P032_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 198 | 32 | P032_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 199 | 32 | P032_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 200 | 32 | P032_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 201 | 32 | P032_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.087S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 202 | 33 | P033_G003 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.29 pt. Touch tolerance: 0.05 pt. | gap_pt=0.29; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P033_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.29 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 203 | 33 | P033_G004 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 204 | 33 | P033_G005 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 205 | 33 | P033_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.090S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 206 | 34 | P034_G001 | Medium | FAIL | Correction Required | Delta Symbol | Green delta is present in a context where it should be absent | Green delta is present in a context where it should be absent | delta_ids=P034_G001_D01 | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 207 | 34 | P034_G001 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 208 | 34 | P034_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Green delta is not allowed in this context | Green delta is not allowed in this context | delta_note_group=False; green_disallowed=True | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 209 | 34 | P034_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 210 | 34 | P034_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 36.451 pt. Touch tolerance: 0.05 pt. | gap_pt=36.451; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P034_G001|P034_G002; comp_delta_groups=P034_G002|P034_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=36.451 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 211 | 34 | P034_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 212 | 34 | P034_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 213 | 34 | P034_G003 | Medium | FAIL | Correction Required | Delta Symbol | Green delta is present in a context where it should be absent | Green delta is present in a context where it should be absent | delta_ids=P034_G003_D01 | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 214 | 34 | P034_G003 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 215 | 34 | P034_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Green delta is not allowed in this context | Green delta is not allowed in this context | delta_note_group=False; green_disallowed=True | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 216 | 34 | P034_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 217 | 34 | P034_G004 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 38.097 pt. Touch tolerance: 0.05 pt. | gap_pt=38.097; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P034_G003|P034_G004; comp_delta_groups=P034_G004|P034_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=38.097 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 218 | 34 | P034_G004 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 219 | 34 | P034_G004_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 220 | 34 | P034_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.091S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 221 | 35 | P035_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.324 pt. Touch tolerance: 0.05 pt. | gap_pt=0.324; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.324 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 222 | 35 | P035_G001_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 223 | 35 | P035_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.316 pt. Touch tolerance: 0.05 pt. | gap_pt=0.316; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.316 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 224 | 35 | P035_G002_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 225 | 35 | P035_G003 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 13.94 pt. Touch tolerance: 0.05 pt. | gap_pt=13.94; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=13.94 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 226 | 35 | P035_G003_D01 | Medium | FAIL | Correction Required | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 227 | 35 | P035_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.092S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 228 | 36 | P036_G001 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 229 | 36 | P036_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 37.339 pt. Touch tolerance: 0.05 pt. | gap_pt=37.339; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P036_G002|P036_G003; comp_delta_groups=P036_G003|P036_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=37.339 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 230 | 36 | P036_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 231 | 36 | P036_G003 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 232 | 36 | P036_G004 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 233 | 36 | P036_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 234 | 37 | P037_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 59.543 pt. Touch tolerance: 0.05 pt. | gap_pt=59.543; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P037_G004|P037_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=59.543 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 235 | 37 | P037_G002 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 51.855 pt. Touch tolerance: 0.05 pt. | gap_pt=51.855; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P037_G003|P037_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=51.855 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 236 | 37 | P037_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0727; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
| 237 | 38 | P038_G001 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 163.353 pt. Touch tolerance: 0.05 pt. | gap_pt=163.353; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P038_G005|P038_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=163.353 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 238 | 38 | P038_G002 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 239 | 38 | P038_G003 | Medium | FAIL | Correction Required | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 240 | 38 | P038_G004 | High | FAIL | Correction Required | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.227 pt. Touch tolerance: 0.05 pt. | gap_pt=0.227; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P038_G004; old_touch=PASS; old_corr=PASS; old_gap_pt=0.227 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 241 | 38 | P038_PRELIMINARY_TAG | High | FAIL | Correction Required | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S04; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | |
Accepted by Operational
168 worksheet rows · 11 columns
| 1 | Accepted by Operational | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Strict-reference findings accepted by the selected operational profile. Use for profile-hardening conversations. | ||||||||||
| 3 | |||||||||||
| 4 | Page | Object ID | Result | Operational | Strict | Check Area | Check | Reason | Observed | Expected | Evidence |
| 5 | 5 | P005_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3939 in; height=0.3411 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_005_P005_G001_D01_delta_size.png |
| 6 | 5 | P005_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3939 in; height=0.3411 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_005_P005_G002_D01_delta_size.png |
| 7 | 5 | P005_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3939 in; height=0.3411 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_005_P005_G003_D01_delta_size.png |
| 8 | 5 | P005_G004_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3939 in; height=0.3411 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_005_P005_G004_D01_delta_size.png |
| 9 | 5 | P005_G005_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3939 in; height=0.3411 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_005_P005_G005_D01_delta_size.png |
| 10 | 6 | P006_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_006_P006_G001_D01_delta_size.png |
| 11 | 6 | P006_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_006_P006_G002_D01_delta_size.png |
| 12 | 6 | P006_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_006_P006_G003_D01_delta_size.png |
| 13 | 6 | P006_G004_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_006_P006_G004_D01_delta_size.png |
| 14 | 7 | P007_G001 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_007_P007_G001_green_hatch_lineweight.png |
| 15 | 7 | P007_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_007_P007_G001_D01_delta_size.png |
| 16 | 7 | P007_G002 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_007_P007_G002_green_hatch_lineweight.png |
| 17 | 7 | P007_G002 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1562 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_007_P007_G002_green_hatch_spacing.png |
| 18 | 7 | P007_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_007_P007_G002_D01_delta_size.png |
| 19 | 7 | P007_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_007_P007_G003_green_hatch_lineweight.png |
| 20 | 7 | P007_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1562 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_007_P007_G003_green_hatch_spacing.png |
| 21 | 7 | P007_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_007_P007_G003_D01_delta_size.png |
| 22 | 8 | P008_G001 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_008_P008_G001_green_hatch_lineweight.png |
| 23 | 8 | P008_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_008_P008_G001_D01_delta_size.png |
| 24 | 8 | P008_G002 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_008_P008_G002_green_hatch_lineweight.png |
| 25 | 8 | P008_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_008_P008_G002_D01_delta_size.png |
| 26 | 8 | P008_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_008_P008_G003_green_hatch_lineweight.png |
| 27 | 8 | P008_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_008_P008_G003_D01_delta_size.png |
| 28 | 8 | P008_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 63.032 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_008_P008_G004_cloud_ridge_angle.png |
| 29 | 8 | P008_G004_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6962 in; height=0.6029 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_008_P008_G004_D01_delta_size.png |
| 30 | 9 | P009_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 62.382 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_009_P009_G002_cloud_ridge_angle.png |
| 31 | 11 | P011_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.427 in; height=0.3698 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_011_P011_G001_D01_delta_size.png |
| 32 | 15 | P015_G001 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_015_P015_G001_green_hatch_lineweight.png |
| 33 | 16 | P016_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G003_cloud_lineweight.png |
| 34 | 16 | P016_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1611 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_016_P016_G003_green_hatch_spacing.png |
| 35 | 16 | P016_G005 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G005_cloud_lineweight.png |
| 36 | 16 | P016_G005 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1002 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_016_P016_G005_green_hatch_spacing.png |
| 37 | 16 | P016_G008 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G008_cloud_lineweight.png |
| 38 | 16 | P016_G008 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1004 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_016_P016_G008_green_hatch_spacing.png |
| 39 | 16 | P016_G009 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G009_cloud_lineweight.png |
| 40 | 16 | P016_G010 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G010_cloud_lineweight.png |
| 41 | 16 | P016_G011 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G011_cloud_lineweight.png |
| 42 | 16 | P016_G012 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G012_cloud_lineweight.png |
| 43 | 16 | P016_G012 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.877 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G012_cloud_ridge_angle.png |
| 44 | 16 | P016_G013 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G013_cloud_lineweight.png |
| 45 | 16 | P016_G014 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G014_cloud_lineweight.png |
| 46 | 16 | P016_G015 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G015_cloud_lineweight.png |
| 47 | 16 | P016_G015 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 70.862 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G015_cloud_ridge_angle.png |
| 48 | 16 | P016_G016 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G016_cloud_lineweight.png |
| 49 | 16 | P016_G017 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G017_cloud_lineweight.png |
| 50 | 16 | P016_G018 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_016_P016_G018_cloud_lineweight.png |
| 51 | 17 | P017_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.114 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_017_P017_G003_cloud_ridge_angle.png |
| 52 | 17 | P017_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_017_P017_G004_cloud_lineweight.png |
| 53 | 17 | P017_G004 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_017_P017_G004_green_hatch_lineweight.png |
| 54 | 18 | P018_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_018_P018_G001_cloud_lineweight.png |
| 55 | 19 | P019_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_019_P019_G001_cloud_lineweight.png |
| 56 | 20 | P020_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_020_P020_G002_cloud_lineweight.png |
| 57 | 20 | P020_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.988 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_020_P020_G002_cloud_ridge_angle.png |
| 58 | 20 | P020_G002 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_020_P020_G002_green_hatch_lineweight.png |
| 59 | 21 | P021_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_021_P021_G001_cloud_lineweight.png |
| 60 | 21 | P021_G001 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_021_P021_G001_green_hatch_lineweight.png |
| 61 | 23 | P023_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_023_P023_G001_cloud_lineweight.png |
| 62 | 23 | P023_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_023_P023_G002_cloud_lineweight.png |
| 63 | 26 | P026_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_026_P026_G001_cloud_lineweight.png |
| 64 | 26 | P026_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.988 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_026_P026_G001_cloud_ridge_angle.png |
| 65 | 27 | P027_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_027_P027_G001_cloud_lineweight.png |
| 66 | 27 | P027_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.989 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_027_P027_G001_cloud_ridge_angle.png |
| 67 | 28 | P028_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_028_P028_G001_cloud_lineweight.png |
| 68 | 29 | P029_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G001_cloud_lineweight.png |
| 69 | 29 | P029_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G002_cloud_lineweight.png |
| 70 | 29 | P029_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G003_cloud_lineweight.png |
| 71 | 29 | P029_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G004_cloud_lineweight.png |
| 72 | 29 | P029_G005 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G005_cloud_lineweight.png |
| 73 | 29 | P029_G006 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G006_cloud_lineweight.png |
| 74 | 29 | P029_G007 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G007_cloud_lineweight.png |
| 75 | 29 | P029_G008 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G008_cloud_lineweight.png |
| 76 | 29 | P029_G009 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G009_cloud_lineweight.png |
| 77 | 29 | P029_G010 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G010_cloud_lineweight.png |
| 78 | 29 | P029_G010 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.528 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G010_cloud_ridge_angle.png |
| 79 | 29 | P029_G011 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G011_cloud_lineweight.png |
| 80 | 29 | P029_G012 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G012_cloud_lineweight.png |
| 81 | 29 | P029_G013 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G013_cloud_lineweight.png |
| 82 | 29 | P029_G014 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G014_cloud_lineweight.png |
| 83 | 29 | P029_G015 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_029_P029_G015_cloud_lineweight.png |
| 84 | 30 | P030_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G001_cloud_lineweight.png |
| 85 | 30 | P030_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G001_D01_delta_size.png |
| 86 | 30 | P030_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G002_cloud_lineweight.png |
| 87 | 30 | P030_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G002_D01_delta_size.png |
| 88 | 30 | P030_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G003_cloud_lineweight.png |
| 89 | 30 | P030_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G003_D01_delta_size.png |
| 90 | 30 | P030_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G004_cloud_lineweight.png |
| 91 | 30 | P030_G004_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G004_D01_delta_size.png |
| 92 | 30 | P030_G005 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G005_cloud_lineweight.png |
| 93 | 30 | P030_G005_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G005_D01_delta_size.png |
| 94 | 30 | P030_G006 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G006_cloud_lineweight.png |
| 95 | 30 | P030_G006_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G006_D01_delta_size.png |
| 96 | 30 | P030_G007 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G007_cloud_lineweight.png |
| 97 | 30 | P030_G007_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G007_D01_delta_size.png |
| 98 | 30 | P030_G008 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G008_cloud_lineweight.png |
| 99 | 30 | P030_G008_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G008_D01_delta_size.png |
| 100 | 30 | P030_G009 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G009_cloud_lineweight.png |
| 101 | 30 | P030_G009_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G009_D01_delta_size.png |
| 102 | 30 | P030_G010 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G010_cloud_lineweight.png |
| 103 | 30 | P030_G010_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G010_D01_delta_size.png |
| 104 | 30 | P030_G011 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G011_cloud_lineweight.png |
| 105 | 30 | P030_G011_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G011_D01_delta_size.png |
| 106 | 30 | P030_G012 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G012_cloud_lineweight.png |
| 107 | 30 | P030_G012 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.188 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G012_cloud_ridge_angle.png |
| 108 | 30 | P030_G012_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G012_D01_delta_size.png |
| 109 | 30 | P030_G013 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G013_cloud_lineweight.png |
| 110 | 30 | P030_G013_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G013_D01_delta_size.png |
| 111 | 30 | P030_G014 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G014_cloud_lineweight.png |
| 112 | 30 | P030_G014_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G014_D01_delta_size.png |
| 113 | 30 | P030_G015 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G015_cloud_lineweight.png |
| 114 | 30 | P030_G015_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G015_D01_delta_size.png |
| 115 | 30 | P030_G016 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G016_cloud_lineweight.png |
| 116 | 30 | P030_G016_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G016_D01_delta_size.png |
| 117 | 30 | P030_G017 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G017_cloud_lineweight.png |
| 118 | 30 | P030_G017_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G017_D01_delta_size.png |
| 119 | 30 | P030_G018 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G018_cloud_lineweight.png |
| 120 | 30 | P030_G018_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G018_D01_delta_size.png |
| 121 | 30 | P030_G019 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G019_cloud_lineweight.png |
| 122 | 30 | P030_G019_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G019_D01_delta_size.png |
| 123 | 30 | P030_G020 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G020_cloud_lineweight.png |
| 124 | 30 | P030_G020 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.491 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G020_cloud_ridge_angle.png |
| 125 | 30 | P030_G020_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G020_D01_delta_size.png |
| 126 | 30 | P030_G021 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.24 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G021_cloud_lineweight.png |
| 127 | 30 | P030_G021_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G021_D01_delta_size.png |
| 128 | 30 | P030_G022 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G022_cloud_lineweight.png |
| 129 | 30 | P030_G022_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G022_D01_delta_size.png |
| 130 | 30 | P030_G023 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G023_cloud_lineweight.png |
| 131 | 30 | P030_G023_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G023_D01_delta_size.png |
| 132 | 30 | P030_G024 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G024_cloud_lineweight.png |
| 133 | 30 | P030_G024_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G024_D01_delta_size.png |
| 134 | 30 | P030_G025 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G025_cloud_lineweight.png |
| 135 | 30 | P030_G025_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G025_D01_delta_size.png |
| 136 | 30 | P030_G026 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G026_cloud_lineweight.png |
| 137 | 30 | P030_G026_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G026_D01_delta_size.png |
| 138 | 30 | P030_G027 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G027_cloud_lineweight.png |
| 139 | 30 | P030_G027_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G027_D01_delta_size.png |
| 140 | 30 | P030_G028 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_030_P030_G028_cloud_lineweight.png |
| 141 | 30 | P030_G028_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.4665 in; height=0.404 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_030_P030_G028_D01_delta_size.png |
| 142 | 31 | P031_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_031_P031_G001_cloud_lineweight.png |
| 143 | 31 | P031_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_031_P031_G002_cloud_lineweight.png |
| 144 | 31 | P031_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_031_P031_G003_cloud_lineweight.png |
| 145 | 31 | P031_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_031_P031_G004_cloud_lineweight.png |
| 146 | 32 | P032_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_032_P032_G001_cloud_lineweight.png |
| 147 | 32 | P032_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_032_P032_G002_cloud_lineweight.png |
| 148 | 32 | P032_G002 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.832 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_032_P032_G002_cloud_ridge_angle.png |
| 149 | 32 | P032_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_032_P032_G003_cloud_lineweight.png |
| 150 | 33 | P033_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_033_P033_G003_cloud_lineweight.png |
| 151 | 33 | P033_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.552 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_033_P033_G003_cloud_ridge_angle.png |
| 152 | 33 | P033_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_033_P033_G003_green_hatch_lineweight.png |
| 153 | 33 | P033_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_033_P033_G004_cloud_lineweight.png |
| 154 | 33 | P033_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 70.743 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_033_P033_G004_cloud_ridge_angle.png |
| 155 | 33 | P033_G004 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_033_P033_G004_green_hatch_lineweight.png |
| 156 | 33 | P033_G005 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.816 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_033_P033_G005_cloud_ridge_angle.png |
| 157 | 34 | P034_G001 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_034_P034_G001_green_hatch_lineweight.png |
| 158 | 34 | P034_G003 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud lineweight out of standard | Cloud lineweight out of standard | 0.238 pt | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_034_P034_G003_cloud_lineweight.png |
| 159 | 34 | P034_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_034_P034_G003_green_hatch_lineweight.png |
| 160 | 35 | P035_G001_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3855 in; height=0.3339 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_035_P035_G001_D01_delta_size.png |
| 161 | 35 | P035_G002_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3848 in; height=0.3333 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_035_P035_G002_D01_delta_size.png |
| 162 | 35 | P035_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.167 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_035_P035_G003_green_hatch_spacing.png |
| 163 | 35 | P035_G003_D01 | Accepted by Operational | PASS | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.3848 in; height=0.3333 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Previews/delta_final_035_P035_G003_D01_delta_size.png |
| 164 | 37 | P037_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.641 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_037_P037_G004_cloud_ridge_angle.png |
| 165 | 38 | P038_G001 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.878 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_038_P038_G001_cloud_ridge_angle.png |
| 166 | 38 | P038_G003 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.1586 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_038_P038_G003_green_hatch_spacing.png |
| 167 | 38 | P038_G004 | Accepted by Operational | PASS | FAIL | Revision Cloud | Cloud ridge angle outside standard | Cloud ridge angle out of standard | 71.505 deg | See configured project profile and strict reference standard. | Visual_Evidence/Previews/delta_final_038_P038_G004_cloud_ridge_angle.png |
| 168 | 38 | P038_G005 | Accepted by Operational | PASS | FAIL | Green Removal Hatching | Green hatch lineweight out of standard | Green hatch lineweight out of standard | 0.48 pt | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Previews/delta_final_038_P038_G005_green_hatch_lineweight.png |
Page Summary
42 worksheet rows · 18 columns
| 1 | Page Summary | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Page-level validation status with correction-required, accepted-operational, and advisory-review conditions summarized separately. | |||||||||||||||||
| 3 | ||||||||||||||||||
| 4 | Page | Result | Operational | Strict Reference | Actionable Issue Count | Actionable Issue Summary | Accepted by Operational Count | Accepted by Operational Summary | Advisory Review Count | Advisory Review Summary | Drawing ID | Sheet Title | Sheet REV | Title Block | Title Block Extract | Revision History | Coversheet | Delta / Cloud |
| 5 | 1 | FAIL | FAIL | FAIL | 1 | Sheet REV matches current WBS4 REV (1) | 0 | 0 | 0238-000.002S01 | COVER & INDEX SHEET – CONTROL | 2A | FAIL | FAIL | N/A | PASS | PASS | ||
| 6 | 2 | FAIL | FAIL | FAIL | 1 | PE stamp present on every IFC binder page (1) | 0 | 0 | 0238-000.002S02-1 | COVER & INDEX SHEET – CONTROL | 2A | FAIL | FAIL | N/A | PASS | |||
| 7 | 3 | FAIL | FAIL | FAIL | 1 | PE stamp present on every IFC binder page (1) | 0 | 0 | 0238-000.002S02-2 | COVER & INDEX SHEET – CONTROL | 2A | FAIL | FAIL | N/A | PASS | |||
| 8 | 4 | PASS | PASS | PASS | 0 | No selected-mode failures | 0 | 0 | 0238-000.003S01 | BILL OF MATERIAL-CONTROL | PASS | PASS | N/A | PASS | ||||
| 9 | 5 | FAIL | FAIL | FAIL | 6 | Red/green connector color is incorrect (4); Sheet REV matches current WBS4 REV (1); Preliminary tag required on drawing page (1) | 5 | Delta symbol size outside standard (5) | 3 | Red cloud boundary contains unintended content (3) | 0238-003.002S01 | SCHEMATIC DIAGRAM | 1A | FAIL | FAIL | N/A | FAIL | |
| 10 | 6 | FAIL | FAIL | FAIL | 5 | Delta must physically touch cloud (2); Sheet REV matches current WBS4 REV (1); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 4 | Delta symbol size outside standard (4) | 4 | Red cloud boundary contains unintended content (4) | 0238-005.004S01 | PANEL ELEVATION | 1A | FAIL | FAIL | N/A | FAIL | |
| 11 | 7 | FAIL | FAIL | FAIL | 5 | Delta must physically touch cloud (2); Sheet REV matches current WBS4 REV (1); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 8 | Green hatch lineweight out of standard (3); Delta symbol size outside standard (3); Green hatch spacing outside standard (2) | 0 | 0238-005.004S01-R | REMOVAL DRAWING – CONTROL | 1A | FAIL | FAIL | N/A | FAIL | ||
| 12 | 8 | FAIL | FAIL | FAIL | 11 | Title block asset name and asset code present (1); Sheet title present (1); Sheet description present (1); Internal-information text present (1); Other (7) | 8 | Delta symbol size outside standard (4); Green hatch lineweight out of standard (3); Cloud ridge angle outside standard (1) | 1 | Red cloud boundary contains unintended content (1) | 0238-005.005S01 | 3A | FAIL | FAIL | N/A | FAIL | ||
| 13 | 9 | FAIL | FAIL | FAIL | 13 | Delta symbol size outside standard (7); Green hatch spacing outside standard (3); Delta must physically touch cloud (2); Preliminary tag required on drawing page (1) | 1 | Cloud ridge angle outside standard (1) | 4 | Red cloud boundary contains unintended content (4) | 0238-005.020S01 | PANEL ELEVATION | 3A | PASS | PASS | N/A | FAIL | |
| 14 | 10 | FAIL | FAIL | FAIL | 5 | Green hatch spacing outside standard (2); Delta symbol size outside standard (2); Preliminary tag required on drawing page (1) | 0 | 0 | 0238-005.021S01 | PANEL ELEVATION | 2A | PASS | PASS | N/A | FAIL | |||
| 15 | 11 | FAIL | FAIL | FAIL | 10 | Title block asset name and asset code present (1); Sheet title present (1); Sheet description present (1); Internal-information text present (1); Other (6) | 1 | Delta symbol size outside standard (1) | 0 | 0238-008.010S01 | 7A | FAIL | FAIL | N/A | PASS | |||
| 16 | 12 | FAIL | FAIL | FAIL | 1 | Preliminary tag required on drawing page (1) | 0 | 1 | Red cloud boundary contains unintended content (1) | 0238-008.012S01 | SCHEMATIC DIAGRAM | 1A | PASS | PASS | N/A | REVIEW | ||
| 17 | 13 | FAIL | FAIL | FAIL | 3 | Sheet REV matches current WBS4 REV (1); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 0 | 1 | Red cloud boundary contains unintended content (1) | 0238-008.012S02 | SCHEMATIC DIAGRAM | 2A | FAIL | FAIL | N/A | FAIL | ||
| 18 | 14 | FAIL | FAIL | FAIL | 3 | Red/green connector color is incorrect (2); Preliminary tag required on drawing page (1) | 0 | 1 | Red cloud boundary contains unintended content (1) | 0238-008.016S01 | WIRING DIAGRAM | 5A | PASS | PASS | N/A | FAIL | ||
| 19 | 15 | FAIL | FAIL | FAIL | 2 | Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 1 | Green hatch lineweight out of standard (1) | 1 | Red cloud boundary contains unintended content (1) | 0238-008.032S01 | WIRING DIAGRAM | 14A | PASS | PASS | N/A | FAIL | |
| 20 | 16 | FAIL | FAIL | FAIL | 9 | Delta must physically touch cloud (5); Red/green connector color is incorrect (2); Sheet REV matches current WBS4 REV (1); Preliminary tag required on drawing page (1) | 18 | Cloud lineweight out of standard (13); Green hatch spacing outside standard (3); Cloud ridge angle outside standard (2) | 5 | Red cloud boundary contains unintended content (5) | 0238-008.033S01 | WIRING DIAGRAM | 7A | FAIL | FAIL | N/A | FAIL | |
| 21 | 17 | FAIL | FAIL | FAIL | 3 | Red/green connector color is incorrect (1); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 3 | Cloud ridge angle outside standard (1); Cloud lineweight out of standard (1); Green hatch lineweight out of standard (1) | 2 | Red cloud boundary contains unintended content (2) | 0238-008.051S01 | METERING AND RELAYING DIAGRAM | 7A | PASS | PASS | N/A | FAIL | |
| 22 | 18 | FAIL | FAIL | FAIL | 4 | Delta symbol size outside standard (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 1 | Cloud lineweight out of standard (1) | 1 | Red cloud boundary contains unintended content (1) | 0238-008.053S01 | WIRING DIAGRAM | 7A | PASS | PASS | N/A | FAIL | |
| 23 | 19 | FAIL | FAIL | FAIL | 4 | Delta symbol size outside standard (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 1 | Cloud lineweight out of standard (1) | 0 | 0238-008.053S01-R | REMOVAL DRAWING – CONTROL | 7A | PASS | PASS | N/A | FAIL | ||
| 24 | 20 | FAIL | FAIL | FAIL | 4 | Red/green connector color is incorrect (2); Green hatch spacing outside standard (1); Preliminary tag required on drawing page (1) | 3 | Cloud lineweight out of standard (1); Cloud ridge angle outside standard (1); Green hatch lineweight out of standard (1) | 1 | Red cloud boundary contains unintended content (1) | 0238-008.054S01 | SCHEMATIC DIAGRAM | 7A | PASS | PASS | N/A | FAIL | |
| 25 | 21 | FAIL | FAIL | FAIL | 1 | Preliminary tag required on drawing page (1) | 2 | Cloud lineweight out of standard (1); Green hatch lineweight out of standard (1) | 0 | 0238-008.055S01 | SCHEMATIC DIAGRAM | 5A | PASS | PASS | N/A | PASS | ||
| 26 | 22 | FAIL | FAIL | FAIL | 1 | Preliminary tag required on drawing page (1) | 0 | 0 | 0238-008.055S02 | SCHEMATIC DIAGRAM | 0A | PASS | PASS | N/A | PASS | |||
| 27 | 23 | FAIL | FAIL | FAIL | 4 | Delta symbol size outside standard (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 2 | Cloud lineweight out of standard (2) | 1 | Red cloud boundary contains unintended content (1) | 0238-008.056S01 | SCHEMATIC DIAGRAM | 6A | PASS | PASS | N/A | FAIL | |
| 28 | 24 | FAIL | FAIL | FAIL | 1 | Preliminary tag required on drawing page (1) | 0 | 2 | Red cloud boundary contains unintended content (2) | 0238-008.057S01 | SCHEMATIC DIAGRAM | 8A | PASS | PASS | N/A | REVIEW | ||
| 29 | 25 | FAIL | FAIL | FAIL | 3 | Delta must physically touch cloud (1); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 0 | 4 | Red cloud boundary contains unintended content (4) | 0238-008.063S01 | SCHEMATIC DIAGRAM | 8A | PASS | PASS | N/A | FAIL | ||
| 30 | 26 | FAIL | FAIL | FAIL | 7 | Delta symbol size outside standard (2); Green hatch spacing outside standard (1); Delta must physically touch cloud (1); Delta lineweight outside standard (1); Other (2) | 2 | Cloud lineweight out of standard (1); Cloud ridge angle outside standard (1) | 1 | Delta font out of standard (1) | 0283-008.063S01-R | REMOVAL DRAWING – CONTROL | 8A | PASS | PASS | N/A | FAIL | |
| 31 | 27 | FAIL | FAIL | FAIL | 4 | Delta symbol size outside standard (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 2 | Cloud lineweight out of standard (1); Cloud ridge angle outside standard (1) | 1 | Red cloud boundary contains unintended content (1) | 0238-008.070S02 | WIRING DIAGRAM | 6A | PASS | PASS | N/A | FAIL | |
| 32 | 28 | FAIL | FAIL | FAIL | 6 | Delta lineweight outside standard (2); Delta symbol size outside standard (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 1 | Cloud lineweight out of standard (1) | 0 | 0238-008.070S02-R | REMOVAL DRAWING – CONTROL | 6A | PASS | PASS | N/A | FAIL | ||
| 33 | 29 | FAIL | FAIL | FAIL | 22 | Delta lineweight outside standard (16); Delta must physically touch cloud (4); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 16 | Cloud lineweight out of standard (15); Cloud ridge angle outside standard (1) | 15 | Red cloud boundary contains unintended content (15) | 0238-008.086S01 | WIRING DIAGRAM | 8A | PASS | PASS | N/A | FAIL | |
| 34 | 30 | FAIL | FAIL | FAIL | 36 | Delta lineweight outside standard (29); Delta must physically touch cloud (5); Delta symbol size outside standard (1); Preliminary tag required on drawing page (1) | 58 | Cloud lineweight out of standard (28); Delta symbol size outside standard (28); Cloud ridge angle outside standard (2) | 0 | 0238-008.086S01-R | REMOVAL DRAWING – CONTROL | 8A | PASS | PASS | N/A | FAIL | ||
| 35 | 31 | FAIL | FAIL | FAIL | 13 | Delta lineweight outside standard (4); Delta symbol size outside standard (4); Delta must physically touch cloud (2); Green hatch spacing outside standard (2); Other (1) | 4 | Cloud lineweight out of standard (4) | 0 | 0238-008.086S02 | WIRING DIAGRAM | 8A | PASS | PASS | N/A | FAIL | ||
| 36 | 32 | FAIL | FAIL | FAIL | 8 | Delta lineweight outside standard (3); Delta symbol size outside standard (3); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 4 | Cloud lineweight out of standard (3); Cloud ridge angle outside standard (1) | 0 | 0238-008.087S01 | WIRING DIAGRAM | 6A | PASS | PASS | N/A | FAIL | ||
| 37 | 33 | FAIL | FAIL | FAIL | 4 | Red/green connector color is incorrect (2); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 7 | Cloud ridge angle outside standard (3); Cloud lineweight out of standard (2); Green hatch lineweight out of standard (2) | 3 | Red cloud boundary contains unintended content (3) | 0238-008.090S01 | SCHEMATIC DIAGRAM | 1A | PASS | PASS | N/A | FAIL | |
| 38 | 34 | FAIL | FAIL | FAIL | 15 | Red/green connector color is incorrect (4); Delta letter/number missing or unreadable (4); Green delta is present in a context where it should be absent (2); Green delta is not allowed in this context (2); Other (3) | 3 | Green hatch lineweight out of standard (2); Cloud lineweight out of standard (1) | 6 | Delta font out of standard (4); Red cloud boundary contains unintended content (2) | 0238-008.091S02 | WIRING DIAGRAM | 7A | PASS | PASS | N/A | FAIL | |
| 39 | 35 | FAIL | FAIL | FAIL | 7 | Delta must physically touch cloud (3); Delta letter/number missing or unreadable (3); Preliminary tag required on drawing page (1) | 4 | Delta symbol size outside standard (3); Green hatch spacing outside standard (1) | 5 | Delta font out of standard (3); Red cloud boundary contains unintended content (2) | 0238-008.092S02 | SCHEMATIC DIAGRAM | 4A | PASS | PASS | N/A | FAIL | |
| 40 | 36 | FAIL | FAIL | FAIL | 6 | Red/green connector color is incorrect (4); Delta must physically touch cloud (1); Preliminary tag required on drawing page (1) | 0 | 2 | Red cloud boundary contains unintended content (2) | 0238-008.093S01 | WIRING DIAGRAM | 3A | PASS | PASS | N/A | FAIL | ||
| 41 | 37 | FAIL | FAIL | FAIL | 3 | Delta must physically touch cloud (2); Preliminary tag required on drawing page (1) | 1 | Cloud ridge angle outside standard (1) | 2 | Red cloud boundary contains unintended content (2) | 0238-008.093S02 | WIRING DIAGRAM | 3A | PASS | PASS | N/A | FAIL | |
| 42 | 38 | FAIL | FAIL | FAIL | 5 | Delta must physically touch cloud (2); Red/green connector color is incorrect (2); Preliminary tag required on drawing page (1) | 4 | Cloud ridge angle outside standard (2); Green hatch spacing outside standard (1); Green hatch lineweight out of standard (1) | 3 | Red cloud boundary contains unintended content (3) | 0238-008.093S04 | WIRING DIAGRAM | 3A | PASS | PASS | N/A | FAIL | |
Visual Evidence
311 worksheet rows · 11 columns · 307 embedded evidence images
| 1 | Visual Evidence | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Issue-level evidence for correction-required and advisory-review conditions. Images are bound to the same toolkit, object ID, and check; cross-toolkit page fallbacks are prohibited. | ||||||||||
| 3 | |||||||||||
| 4 | Preview | Page | Object ID | Result | Check Area | Check | Reason | Observed | Expected | Evidence File | Annotated PDF |
| 5 | 1 | 0238-000.002S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=1.0; matched_wbs_rev=2A; sheet_rev=2A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 6 | 2 | 0238-000.002S02-1 | FAIL | Title Block | PE stamp present on every IFC binder page | Required PE stamp is missing or could not be verified on this IFC binder page. | required=YES; present=FAIL; family=INDEX; method=MULTI_PROBE_RING_TEXT_V9; zone=FLOATING_BOM_APPROVAL | A verifiable PE stamp is required on every page of an IFC binder. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 7 | 3 | 0238-000.002S02-2 | FAIL | Title Block | PE stamp present on every IFC binder page | Required PE stamp is missing or could not be verified on this IFC binder page. | required=YES; present=FAIL; family=INDEX; method=MULTI_PROBE_RING_TEXT_V9; zone=FLOATING_BOM_APPROVAL | A verifiable PE stamp is required on every page of an IFC binder. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 8 | 5 | 0238-003.002S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 9 | 5 | P005_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 10 | 5 | P005_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 11 | 5 | P005_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 12 | 5 | P005_G003 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 13 | 5 | P005_G004 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 14 | 5 | P005_G005 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 15 | 5 | P005_G005 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 16 | 5 | P005_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-003.002S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 17 | 6 | 0238-005.004S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 18 | 6 | P006_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 19 | 6 | P006_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.587 pt. Touch tolerance: 0.05 pt. | gap_pt=0.587; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; same_color_connector_or_leader; comp_delta_groups=P006_G004|P006_G003|P006_G002|P006_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.587 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 20 | 6 | P006_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 21 | 6 | P006_G003 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 22 | 6 | P006_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 23 | 6 | P006_G005 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 24 | 6 | P006_G005_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8321 in; height=0.7206 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 25 | 6 | P006_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.004S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 26 | 7 | 0238-005.004S01-R | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=7.0; matched_wbs_rev=1A; sheet_rev=1A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 27 | 7 | P007_G003 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 1.272 pt. Touch tolerance: 0.05 pt. | gap_pt=1.272; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P007_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=1.272 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 28 | 7 | P007_G004 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 29 | 7 | P007_G004_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8157 in; height=0.7064 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 30 | 7 | P007_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0238-005.004S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.4123; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 31 | 8 | 0238-005.005S01 | FAIL | Title Block | Title block asset name and asset code present | Required title-block asset name or asset code is missing or unreadable. | Observed asset: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 32 | 8 | 0238-005.005S01 | FAIL | Title Block | Sheet title present | Sheet title present | Observed title: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 33 | 8 | 0238-005.005S01 | FAIL | Title Block | Sheet description present | Sheet description present | Observed description: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 34 | 8 | 0238-005.005S01 | FAIL | Title Block | Internal-information text present | Internal-information text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |||
| 35 | 8 | 0238-005.005S01 | FAIL | Title Block | Title block logo present | Required title-block logo was not detected in the logo cell. | tb_logo_ok=FAIL | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 36 | 8 | 0238-005.005S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=; matched_wbs_rev=3A; sheet_rev=3A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 37 | 8 | 0238-005.005S01 | FAIL | Title Block | Right-panel current REV present | Right-panel current REV present | Observed sheet_rev: 3A | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 38 | 8 | 0238-005.005S01 | FAIL | Title Block | Scale present | Scale present | Observed scale: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 39 | 8 | 0238-005.005S01 | FAIL | Title Block | Safety warning text present | Safety warning text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |||
| 40 | 8 | P008_G002 | FAIL | Green Removal Hatching | Green removal hatch integrity outside standard | Green removal cloud is missing required hatch evidence. Missing hatch count: 13. | observed_member_count=10; observed_hatch_count=6; observed_visible_line_count=5; observed_measured_line_count=5; missing=13 | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 41 | 8 | P008_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 42 | 8 | P008_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.005S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 43 | 9 | P009_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.681 pt. Touch tolerance: 0.05 pt. | gap_pt=0.681; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P009_G001|P009_G006; old_touch=PASS; old_corr=PASS; old_gap_pt=0.681 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 44 | 9 | P009_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported clipping intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 45 | 9 | P009_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 46 | 9 | P009_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.514 pt. Touch tolerance: 0.05 pt. | gap_pt=0.514; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P009_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.514 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 47 | 9 | P009_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 48 | 9 | P009_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2972 in; height=1.1234 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 49 | 9 | P009_G003 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 50 | 9 | P009_G003_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 51 | 9 | P009_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 52 | 9 | P009_G004_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 53 | 9 | P009_G005 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 54 | 9 | P009_G005_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 55 | 9 | P009_G006 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 56 | 9 | P009_G006_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 57 | 9 | P009_G007 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.4999 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 58 | 9 | P009_G007_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.9988 in; height=0.865 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 59 | 9 | P009_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.020S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 60 | 10 | P010_G001 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6251 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 61 | 10 | P010_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2701 in; height=1.1 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 62 | 10 | P010_G002 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6249 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 63 | 10 | P010_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.2701 in; height=1.1 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 64 | 10 | P010_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-005.021S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 65 | 11 | 0238-008.010S01 | FAIL | Title Block | Title block asset name and asset code present | Required title-block asset name or asset code is missing or unreadable. | Observed asset: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 66 | 11 | 0238-008.010S01 | FAIL | Title Block | Sheet title present | Sheet title present | Observed title: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 67 | 11 | 0238-008.010S01 | FAIL | Title Block | Sheet description present | Sheet description present | Observed description: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 68 | 11 | 0238-008.010S01 | FAIL | Title Block | Internal-information text present | Internal-information text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |||
| 69 | 11 | 0238-008.010S01 | FAIL | Title Block | Title block logo present | Required title-block logo was not detected in the logo cell. | tb_logo_ok=FAIL | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 70 | 11 | 0238-008.010S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=; matched_wbs_rev=7A; sheet_rev=7A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 71 | 11 | 0238-008.010S01 | FAIL | Title Block | Right-panel current REV present | Right-panel current REV present | Observed sheet_rev: 7A | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 72 | 11 | 0238-008.010S01 | FAIL | Title Block | Scale present | Scale present | Observed scale: | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 73 | 11 | 0238-008.010S01 | FAIL | Title Block | Safety warning text present | Safety warning text present | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | |||
| 74 | 11 | P011_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.010S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 75 | 12 | P012_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.940; non_red_area_pt2=22.0; non_red_objects=14; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 76 | 12 | P012_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.012S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.5397; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 77 | 13 | 0238-008.012S02 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=1.0; matched_wbs_rev=2A; sheet_rev=2A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 78 | 13 | P013_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.421 pt. Touch tolerance: 0.05 pt. | gap_pt=0.421; tolerance_pt=0.05; delta_count=1; cloud_path_count=5; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P013_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.421 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 79 | 13 | P013_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.929; non_red_area_pt2=25.1; non_red_objects=13; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 80 | 13 | P013_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.012S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 81 | 14 | P014_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 82 | 14 | P014_G001 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 83 | 14 | P014_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 84 | 14 | P014_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.016S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 85 | 15 | P015_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 48.323 pt. Touch tolerance: 0.05 pt. | gap_pt=48.323; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P015_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=48.323 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 86 | 15 | P015_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 87 | 15 | P015_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.032S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 88 | 16 | 0238-008.033S01 | FAIL | Title Block | Sheet REV matches current WBS4 REV | Title-block current REV does not match the current WBS revision row | right_panel_rev=2.0; matched_wbs_rev=7A; sheet_rev=7A; sheet_rev_position=S3_R2 | See configured project profile and strict reference standard. | Visual_Evidence/TitleBlock_Annotated.pdf | ||
| 89 | 16 | P016_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 90 | 16 | P016_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 91 | 16 | P016_G003 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.136 pt. Touch tolerance: 0.05 pt. | gap_pt=0.136; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P016_G003|P016_G004; comp_delta_groups=P016_G004|P016_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.136 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 92 | 16 | P016_G003 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 93 | 16 | P016_G004 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.149 pt. Touch tolerance: 0.05 pt. | gap_pt=0.149; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P016_G003|P016_G004; comp_delta_groups=P016_G004|P016_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.149 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 94 | 16 | P016_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 95 | 16 | P016_G004 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 96 | 16 | P016_G006 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 97 | 16 | P016_G007 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 98 | 16 | P016_G013 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta/cloud edge gap could not be measured, so required physical touch could not be proven. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; same_color_connector_or_leader; comp_delta_groups=P016_G014; old_touch=PASS; old_corr=PASS; old_gap_pt= | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 99 | 16 | P016_G016 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.073 pt. Touch tolerance: 0.05 pt. | gap_pt=0.073; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P016_G016; old_touch=PASS; old_corr=PASS; old_gap_pt=0.073 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 100 | 16 | P016_G018 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.169 pt. Touch tolerance: 0.05 pt. | gap_pt=0.169; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P016_G018; old_touch=PASS; old_corr=PASS; old_gap_pt=0.169 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 101 | 16 | P016_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.033S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 102 | 17 | P017_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 103 | 17 | P017_G001 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 104 | 17 | P017_G001_D02 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.2084 in; height=0.1805 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 105 | 17 | P017_G003 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 106 | 17 | P017_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING; drawing_number=0238-008.051S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 107 | 18 | P018_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 108 | 18 | P018_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.8267 in; height=0.7159 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 109 | 18 | P018_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 110 | 18 | P018_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7294 in; height=0.6317 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 111 | 18 | P018_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.053S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0983; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 112 | 19 | P019_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6109 in; height=0.5291 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 113 | 19 | P019_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 114 | 19 | P019_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7432 in; height=0.6437 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 115 | 19 | P019_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0238-008.053S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.7026; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 116 | 20 | P020_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 117 | 20 | P020_G001 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 118 | 20 | P020_G002 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 119 | 20 | P020_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 120 | 20 | P020_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.054S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 121 | 21 | P021_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.055S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 122 | 22 | P022_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.055S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.2024; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 123 | 23 | P023_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7476 in; height=0.6474 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 124 | 23 | P023_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.282 pt. Touch tolerance: 0.05 pt. | gap_pt=0.282; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P023_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.282 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 125 | 23 | P023_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 126 | 23 | P023_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7476 in; height=0.6474 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 127 | 23 | P023_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.056S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 128 | 24 | P024_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 129 | 24 | P024_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 130 | 24 | P024_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.057S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.3035; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 131 | 25 | P025_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.989; non_red_area_pt2=4.7; non_red_objects=8; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 132 | 25 | P025_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.988; non_red_area_pt2=3.8; non_red_objects=6; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 133 | 25 | P025_G003 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 134 | 25 | P025_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.991; non_red_area_pt2=4.9; non_red_objects=8; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 135 | 25 | P025_G021 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 136 | 25 | P025_G021_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7544 in; height=0.6534 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 137 | 25 | P025_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.063S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 138 | 26 | P026_G001 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.9998 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 139 | 26 | P026_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6741 in; height=0.5838 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 140 | 26 | P026_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 141 | 26 | P026_G002_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 142 | 26 | P026_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 143 | 26 | P026_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7543 in; height=0.6532 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 144 | 26 | P026_G002_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 145 | 26 | P026_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_REMOVAL; drawing_number=0283-008.063S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0727; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 146 | 27 | P027_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 147 | 27 | P027_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.1281 in; height=0.977 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 148 | 27 | P027_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 149 | 27 | P027_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=1.1281 in; height=0.977 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 150 | 27 | P027_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.070S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 151 | 28 | P028_G001_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 152 | 28 | P028_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7535 in; height=0.6525 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 153 | 28 | P028_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 154 | 28 | P028_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 155 | 28 | P028_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7535 in; height=0.6525 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 156 | 28 | P028_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.070S02-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.7026; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 157 | 29 | P029_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 158 | 29 | P029_G001_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 159 | 29 | P029_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 160 | 29 | P029_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 161 | 29 | P029_G003 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 162 | 29 | P029_G003_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 163 | 29 | P029_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 164 | 29 | P029_G004_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 165 | 29 | P029_G005 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 166 | 29 | P029_G005_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 167 | 29 | P029_G006 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 168 | 29 | P029_G006_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 169 | 29 | P029_G007 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.265 pt. Touch tolerance: 0.05 pt. | gap_pt=0.265; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G007; old_touch=PASS; old_corr=PASS; old_gap_pt=0.265 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 170 | 29 | P029_G007 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 171 | 29 | P029_G007_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 172 | 29 | P029_G008 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.165 pt. Touch tolerance: 0.05 pt. | gap_pt=0.165; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G008; old_touch=PASS; old_corr=PASS; old_gap_pt=0.165 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 173 | 29 | P029_G008 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 174 | 29 | P029_G008_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 175 | 29 | P029_G009 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 176 | 29 | P029_G009_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 177 | 29 | P029_G010 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 178 | 29 | P029_G010_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 179 | 29 | P029_G011 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.991; non_red_area_pt2=1.1; non_red_objects=1; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 180 | 29 | P029_G011_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 181 | 29 | P029_G012 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 182 | 29 | P029_G012_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 183 | 29 | P029_G013 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 184 | 29 | P029_G013_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 185 | 29 | P029_G014 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.261 pt. Touch tolerance: 0.05 pt. | gap_pt=0.261; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P029_G014; old_touch=PASS; old_corr=PASS; old_gap_pt=0.261 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 186 | 29 | P029_G014 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 187 | 29 | P029_G014_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 188 | 29 | P029_G015 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 189 | 29 | P029_G015_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 190 | 29 | P029_G016 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 191 | 29 | P029_G016_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 192 | 29 | P029_G016_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.7474 in; height=0.6472 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 193 | 29 | P029_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0943; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 194 | 30 | P030_G001_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 195 | 30 | P030_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 1.017 pt. Touch tolerance: 0.05 pt. | gap_pt=1.017; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=1.017 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 196 | 30 | P030_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 197 | 30 | P030_G003_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 198 | 30 | P030_G004_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 199 | 30 | P030_G005_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 200 | 30 | P030_G006_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 201 | 30 | P030_G007_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 202 | 30 | P030_G008_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 203 | 30 | P030_G009_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 204 | 30 | P030_G010_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 205 | 30 | P030_G011_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 206 | 30 | P030_G012 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.061 pt. Touch tolerance: 0.05 pt. | gap_pt=0.061; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G012; old_touch=PASS; old_corr=PASS; old_gap_pt=0.061 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 207 | 30 | P030_G012_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 208 | 30 | P030_G013_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 209 | 30 | P030_G014_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 210 | 30 | P030_G015 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.864 pt. Touch tolerance: 0.05 pt. | gap_pt=0.864; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G015; old_touch=PASS; old_corr=PASS; old_gap_pt=0.864 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 211 | 30 | P030_G015_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 212 | 30 | P030_G016_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 213 | 30 | P030_G017_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 214 | 30 | P030_G018_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 215 | 30 | P030_G019 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.371 pt. Touch tolerance: 0.05 pt. | gap_pt=0.371; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P030_G019; old_touch=PASS; old_corr=PASS; old_gap_pt=0.371 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 216 | 30 | P030_G019_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 217 | 30 | P030_G020_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 218 | 30 | P030_G021_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 219 | 30 | P030_G022_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 220 | 30 | P030_G023_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 221 | 30 | P030_G024_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 222 | 30 | P030_G025_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 223 | 30 | P030_G026_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 224 | 30 | P030_G027_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 225 | 30 | P030_G028_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 226 | 30 | P030_G029 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta has no measured revision cloud touching it. Callout, boxed-note, leader-line, or construction-note context cannot override the hard-touch rule. | gap_pt=; tolerance_pt=0.05; delta_count=1; cloud_path_count=0; old_basis=exact_edge_gap_pt | SVS_V9_5: boxed note/delta-anchor cloud-equivalent | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 227 | 30 | P030_G029_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 228 | 30 | P030_G029_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.675 in; height=0.5846 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 229 | 30 | P030_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S01-R; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.8025; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 230 | 31 | P031_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.503 pt. Touch tolerance: 0.05 pt. | gap_pt=0.503; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P031_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.503 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 231 | 31 | P031_G001_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 232 | 31 | P031_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 233 | 31 | P031_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.334 pt. Touch tolerance: 0.05 pt. | gap_pt=0.334; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P031_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.334 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 234 | 31 | P031_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 235 | 31 | P031_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 236 | 31 | P031_G003 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 237 | 31 | P031_G003_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 238 | 31 | P031_G003_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 239 | 31 | P031_G004 | FAIL | Green Removal Hatching | Green hatch spacing outside standard | Green hatch spacing out of standard | 0.6001 in | Green removal clouds must contain the configured hatch pattern, spacing, and visible hatch count. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 240 | 31 | P031_G004_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 241 | 31 | P031_G004_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 242 | 31 | P031_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.086S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0748; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 243 | 32 | P032_G001_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 244 | 32 | P032_G001_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 245 | 32 | P032_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.307 pt. Touch tolerance: 0.05 pt. | gap_pt=0.307; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P032_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.307 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 246 | 32 | P032_G002_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 247 | 32 | P032_G002_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 248 | 32 | P032_G003_D01 | FAIL | Delta Symbol | Delta lineweight outside standard | Delta lineweight out of standard | 0.24 pt | Delta lineweight must match the configured project standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 249 | 32 | P032_G003_D01 | FAIL | Delta Symbol | Delta symbol size outside standard | Delta size out of standard | side=0.6639 in; height=0.575 in | Delta triangle must match the configured project size tolerance. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 250 | 32 | P032_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.087S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 251 | 33 | P033_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.983; non_red_area_pt2=5.8; non_red_objects=4; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 252 | 33 | P033_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 253 | 33 | P033_G003 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.29 pt. Touch tolerance: 0.05 pt. | gap_pt=0.29; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P033_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=0.29 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 254 | 33 | P033_G004 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 255 | 33 | P033_G005 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 256 | 33 | P033_G005 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 257 | 33 | P033_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.090S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=1.0; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 258 | 34 | P034_G001 | FAIL | Delta Symbol | Green delta is present in a context where it should be absent | Green delta is present in a context where it should be absent | delta_ids=P034_G001_D01 | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 259 | 34 | P034_G001 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 260 | 34 | P034_G001_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 261 | 34 | P034_G001_D01 | FAIL | Delta Symbol | Green delta is not allowed in this context | Green delta is not allowed in this context | delta_note_group=False; green_disallowed=True | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 262 | 34 | P034_G001_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 263 | 34 | P034_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 36.451 pt. Touch tolerance: 0.05 pt. | gap_pt=36.451; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P034_G001|P034_G002; comp_delta_groups=P034_G002|P034_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=36.451 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 264 | 34 | P034_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; zero supported colored-content coverage; missing, NaN, infinite or invalid coverage values; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=unmeasured; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 265 | 34 | P034_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 266 | 34 | P034_G002_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 267 | 34 | P034_G002_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 268 | 34 | P034_G003 | FAIL | Delta Symbol | Green delta is present in a context where it should be absent | Green delta is present in a context where it should be absent | delta_ids=P034_G003_D01 | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 269 | 34 | P034_G003 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 270 | 34 | P034_G003_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 271 | 34 | P034_G003_D01 | FAIL | Delta Symbol | Green delta is not allowed in this context | Green delta is not allowed in this context | delta_note_group=False; green_disallowed=True | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 272 | 34 | P034_G003_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 273 | 34 | P034_G004 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 38.097 pt. Touch tolerance: 0.05 pt. | gap_pt=38.097; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P034_G003|P034_G004; comp_delta_groups=P034_G004|P034_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=38.097 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 274 | 34 | P034_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; zero supported colored-content coverage; missing, NaN, infinite or invalid coverage values; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=unmeasured; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 275 | 34 | P034_G004 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 276 | 34 | P034_G004_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 277 | 34 | P034_G004_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 278 | 34 | P034_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.091S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 279 | 35 | P035_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.324 pt. Touch tolerance: 0.05 pt. | gap_pt=0.324; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=0.324 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 280 | 35 | P035_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; zero supported colored-content coverage; missing, NaN, infinite or invalid coverage values; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=unmeasured; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 281 | 35 | P035_G001_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 282 | 35 | P035_G001_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 283 | 35 | P035_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.316 pt. Touch tolerance: 0.05 pt. | gap_pt=0.316; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=0.316 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 284 | 35 | P035_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.000; non_red_area_pt2=0.5; non_red_objects=1; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 285 | 35 | P035_G002_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 286 | 35 | P035_G002_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 287 | 35 | P035_G003 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 13.94 pt. Touch tolerance: 0.05 pt. | gap_pt=13.94; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P035_G003; old_touch=PASS; old_corr=PASS; old_gap_pt=13.94 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 288 | 35 | P035_G003_D01 | REVIEW | Delta Symbol | Delta font out of standard | Delta font out of standard | @ pt | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 289 | 35 | P035_G003_D01 | FAIL | Delta Symbol | Delta letter/number missing or unreadable | Delta letter/number missing or unreadable | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | |||
| 290 | 35 | P035_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_SCHEMATIC; drawing_number=0238-008.092S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 291 | 36 | P036_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 292 | 36 | P036_G001 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 293 | 36 | P036_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 37.339 pt. Touch tolerance: 0.05 pt. | gap_pt=37.339; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; arch_or_leader_to_measured_delta:P036_G002|P036_G003; comp_delta_groups=P036_G003|P036_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=37.339 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 294 | 36 | P036_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.888; non_red_area_pt2=17.9; non_red_objects=4; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 295 | 36 | P036_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 296 | 36 | P036_G003 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 297 | 36 | P036_G004 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 298 | 36 | P036_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S01; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 299 | 37 | P037_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 59.543 pt. Touch tolerance: 0.05 pt. | gap_pt=59.543; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P037_G004|P037_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=59.543 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 300 | 37 | P037_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.609; non_red_area_pt2=88.7; non_red_objects=7; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 301 | 37 | P037_G002 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 51.855 pt. Touch tolerance: 0.05 pt. | gap_pt=51.855; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P037_G003|P037_G002; old_touch=PASS; old_corr=PASS; old_gap_pt=51.855 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 302 | 37 | P037_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported clipping intersects coverage box; unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=0.939; non_red_area_pt2=9.3; non_red_objects=3; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 303 | 37 | P037_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S02; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0727; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
| 304 | 38 | P038_G001 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 163.353 pt. Touch tolerance: 0.05 pt. | gap_pt=163.353; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; approved_red_green_connector_color=red; comp_delta_groups=P038_G005|P038_G001; old_touch=PASS; old_corr=PASS; old_gap_pt=163.353 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 305 | 38 | P038_G001 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 306 | 38 | P038_G002 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 307 | 38 | P038_G002 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 308 | 38 | P038_G003 | FAIL | delta_cloud | Red/green connector color is incorrect | Red/green connector color is incorrect | connector_color=green | See configured project profile and strict reference standard. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 309 | 38 | P038_G004 | FAIL | Delta / Cloud Relationship | Delta must physically touch cloud | Delta does not physically touch the associated revision cloud. Measured gap: 0.227 pt. Touch tolerance: 0.05 pt. | gap_pt=0.227; tolerance_pt=0.05; delta_count=1; cloud_path_count=1; old_basis=SVS_V8_4: connector/arch relationship accepted; no_connector_columns; comp_delta_groups=P038_G004; old_touch=PASS; old_corr=PASS; old_gap_pt=0.227 | Delta edge must physically touch the associated revision cloud edge. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 310 | 38 | P038_G004 | REVIEW | Cloud Content | Red cloud boundary contains unintended content | Red installation cloud content coverage requires review: unsupported filled-vector geometry or opacity intersects coverage box; unsupported stroke coverage; cloud boundaries cannot be separated reliably from content; unsupported stroke or raster coverage. No content-purity PASS is established; this estimator is a bounding-box proxy, not a visible-pixel measurement. | red_content_fraction=1.000; non_red_area_pt2=0.0; non_red_objects=0; treatment=review_unmeasured_or_unsupported_coverage | A valid, supported nonzero content-area proxy is required before reporting content-purity PASS. Unsupported or missing coverage requires review in every policy mode. | Visual_Evidence/Delta_Cloud_Annotated.pdf | ||
| 311 | 38 | P038_PRELIMINARY_TAG | FAIL | Preliminary Tag | Preliminary tag required on drawing page | Required drawing page is missing the PRELIMINARY NOT FOR CONSTRUCTION tag | page_type=DRAWING_WIRING; drawing_number=0238-008.093S04; text_layer_match=False; red_ocr_match=False; visual_shape_score=0.0928; basis=not_found | Required drawing pages must include PRELIMINARY NOT FOR CONSTRUCTION tag. | Visual_Evidence/Preliminary_Tag_Annotated.pdf | ||
Recovered Cloud Checks
4 worksheet rows · 10 columns
This sheet contains its original headings and scope note; this run has no recovered-cloud measurement rows.
| 1 | Recovered Cloud Checks | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Recovered native groups only. Positive accepted gaps are not literal touching. Configured color comparison is separate from engineering approval. | |||||||||
| 3 | ||||||||||
| 4 | Page | Group | Contact Result | Gap Lower (pt) | Gap Upper (pt) | Tolerance (pt) | Visibility | Configured Color | Standards Approval | Evidence and Review Basis |
Title Block Review
42 worksheet rows · 75 columns
| 1 | Title Block Review | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Page-level title block output with a client-facing combined Title Block result. Title Block fails when extraction/format checks fail OR revision-history representation fails. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4 | Page | Title Block | Title Block Extract | Revision History | Revision History Reason | Binderfile | Drawingfile | Drawing ID | Project Name | Asset Name | Asset Code | Sheet Title | Sheet Description | Scale | Issued For | Binder Issued For | Seal Page Family | Warning Text | Internal Text | REV From Table | Sheet REV | Sheet REV Position | Matched Section | Matched Row | Row Has WBS | WBS4 Exempt | REV | Date | WBS4 | Revision Description | Extract Status | Right Panel Status | Current Row REV OK | Current Row Date OK | Current Row WBS OK | Current Row Description OK | Seal Present | Seal Probe Zone | Seal Nonwhite Ratio | Seal Valid Circle Count | Seal Nested Circle Pair | Seal Detection Score | Page Status | S1 R1 REV | S1 R1 Date | S1 R1 WBS4 | S1 R1 REVision Description | S1 R2 REV | S1 R2 Date | S1 R2 WBS4 | S1 R2 REVision Description | S2 R1 REV | S2 R1 Date | S2 R1 WBS4 | S2 R1 REVision Description | S2 R2 REV | S2 R2 Date | S2 R2 WBS4 | S2 R2 REVision Description | S3 R1 REV | S3 R1 Date | S3 R1 WBS4 | S3 R1 REVision Description | S3 R2 REV | S3 R2 Date | S3 R2 WBS4 | S3 R2 REVision Description | Spelling Status | Spelling Reason | Master Issued For | Master Issued For Label | Master Issued For Source | REVision Issue Type | REVision Issue Type Match | REVision Issue Type Reason |
| 5 | 1 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-000.002S01.PDF | 0238-000.002S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | COVER & INDEX SHEET – CONTROL | COVER SHEET | NONE | CONSTRUCTION | IFC | INDEX | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 1.0 | 2A | S3_R2 | 3 | 2 | True | False | 2A | 2026/07/06 | A.0000304.009.003.426 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.166748 | 1 | False | 34.54 | FAIL | 1D | 2023/05/31 | A.0000304.009.003.333 | IFC – SFE – TALI-INST TRANSGARD ELECTRIC FENCE | 1C | 2023/05/31 | A.0000304.117.003.303 | IFC – TALI-8425-8424 COMM FOR RELAY ELT – TAM | 1B | 2023/05/31 | A.0000304.073.003.303 | IFC – TALI-8424 RELAY REPLACEMENT – SVS-CMT | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 2A | 2026/07/06 | A.0000304.009.003.426 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 6 | 2 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-000.002S02-1.PDF | 0238-000.002S02-1 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | COVER & INDEX SHEET – CONTROL | INDEX SHEET | NONE | CONSTRUCTION | IFC | INDEX | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 2A | S3_R2 | 3 | 2 | True | False | 2A | 2023/05/31 | A.0000304.009.003.303 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | OK | PASS | PASS | PASS | PASS | PASS | FAIL | FLOATING_BOM_APPROVAL | 0.063306 | 0 | False | 16.985 | FAIL | 1C | 2023/05/31 | A.0000304.117.003.303 | IFC – TALI-8425-8424 COMM FOR RELAY ELT – TAM | 0238-000.002S02-1 | 2A | 2023/05/31 | A.0000304.009.003.303 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||||||||
| 7 | 3 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-000.002S02-2.PDF | 0238-000.002S02-2 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | COVER & INDEX SHEET – CONTROL | INDEX SHEET | NONE | CONSTRUCTION | IFC | INDEX | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 2A | S3_R2 | 3 | 2 | True | False | 2A | 2023/05/31 | A.0000304.009.003.303 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | OK | PASS | PASS | PASS | PASS | PASS | FAIL | FLOATING_BOM_APPROVAL | 0.068076 | 0 | False | 17.478 | FAIL | 1C | 2023/05/31 | A.0000304.117.003.303 | IFC – TALI-8425-8424 COMM FOR RELAY ELT – TAM | 0238-000.002S02-2 | 2A | 2023/05/31 | A.0000304.009.003.303 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||||||||
| 8 | 4 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-000.003S01.PDF | 0238-000.003S01 | SUBSTATION | SUBSTATION | TALI | BILL OF MATERIAL-CONTROL | SHEET 1 0F 1 | NONE | CONSTRUCTION | IFC | BILL_OF_MATERIAL | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY TALI | 0.0 | BOM_EXEMPT | False | True | EXEMPT_BILL_OF_MATERIAL | PASS | EXEMPT | EXEMPT | EXEMPT | EXEMPT | PASS | FLOATING_BOM_APPROVAL | 0.118235 | 2 | True | 87.742 | PASS | NOT_APPLICABLE | BOM / material schedule page exempt from fixed right-title-block label and WBS revision-history label spelling checks. | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | NOT_EVALUATED | Current revision description does not begin with IFC/IFR/IFA; no issue-type comparison was made. | ||||||||||||||||||||||||||||||||
| 9 | 5 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-003.002S01.PDF | 0238-003.002S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | AC & DC BREAKER PANELS, WIRING DIAGRAM (EEE) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 1A | S3_R2 | 3 | 2 | True | False | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.08366 | 2 | True | 99.181 | FAIL | 5 | 1997/05/08 | INSTALL VRC FOR FEEDERS | 6 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 7D | 2023/05/31 | A.0000304.117.003.303 | IFC – TALI INST TRANSGARD ELECTRIC FENCE | 7B | 2023/05/31 | A.0000304.073.003.303 | IFC – TALI-8424 RELAY REPLACEMENT – SVS-CMT | 2A | 2023/05/31 | A.0000304.009.003.303 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||
| 10 | 6 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-005.004S01.PDF | 0238-005.004S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | PANEL ELEVATION | 24.9KV PANEL LAYOUT FRONT VIEW | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 1A | S3_R2 | 3 | 2 | True | False | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.074915 | 2 | True | 98.468 | FAIL | 5 | 1989/02/14 | REVISED PER FINAL FIELD CHECK | 6 | 1993/07/30 | ADD SYNC AND TERM RDG AM, ASSIGN | 4 | 1994/12/13 | FIELD REVISIONS-4 POLE PK-2’S | 5 | 1996/01/12 | FIELD REVISIONS | 6 | 2019/06/17 | – CONVERTED TO MICROSTATION V8 FOR RECORD | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||
| 11 | 7 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-005.004S01-R.PDF | 0238-005.004S01-R | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | REMOVAL DRAWING – CONTROL | PANEL ELEVATION – 24.9KV PANEL LAYOUT FRONT VIEW | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 1A | S3_R2 | 3 | 2 | True | False | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.074424 | 2 | True | 98.501 | FAIL | 6 | 1989/10/30 | FINAL REVISIONS | 4 | 1994/12/13 | FIELD REVISIONS-4 POLE PK-2’S | 3 | 1996/01/12 | FIELD REVISIONS | 7 | 2019/06/17 | – CONVERTED TO MICROSTATION V8 FOR RECORD | 1A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||
| 12 | 8 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-005.005S01.PDF | 0238-005.005S01 | CONSTRUCTION | IFC | ENGINEERING_DRAWING | 3A | S3_R2 | 3 | 2 | True | False | 3A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | FAIL | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.072505 | 2 | True | 98.28 | FAIL | 1 | 1989/10/30 | FIELD REVISIONS | 2 | 1993/07/30 | ADD PK-2, ASSIGN PSC NUMBER, ADD LCU | 3 | 1996/01/12 | FIELD REVISIONS | 2 | 2019/06/17 | – CONVERTED TO MICROSTATION V8 FOR RECORD | 3A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||||||||||
| 13 | 9 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-005.020S01.PDF | 0238-005.020S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | PANEL ELEVATION | 24.9KV UNIT #3 FRONT, PANEL LAYOUT | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 3.0 | 3A | S3_R2 | 3 | 2 | True | False | 3A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.06811 | 2 | True | 97.921 | PASS | 1 | 1994/12/13 | FIELD REVISIONS-4 POLE PK-2’S | 2 | 2019/06/17 | – CONVERTED TO MICROSTATION V8 FOR RECORD | 3A | 2023/05/31 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||
| 14 | 10 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-005.021S01.PDF | 0238-005.021S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | PANEL ELEVATION | 24.9KV UNIT #3 REAR, PANEL LAYOUT | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 2A | S3_R2 | 3 | 2 | True | False | 2A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.06482 | 2 | True | 97.71 | PASS | 1 | 2019/06/17 | CONVERTED TO MICROSTATION FOR V8 RECORD | 2A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||||||||||
| 15 | 11 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.010S01.PDF | 0238-008.010S01 | CONSTRUCTION | IFC | ENGINEERING_DRAWING | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | FAIL | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.115028 | 2 | True | 101.722 | FAIL | 6A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||||||||||||||||||
| 16 | 12 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.012S01.PDF | 0238-008.012S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | ETHERNET SWITCH (RX1501) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 1.0 | 1A | S3_R2 | 3 | 2 | True | False | 1A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.066395 | 2 | True | 97.782 | PASS | 0A | 2025/05/31 | A.0000506.067.003.002 | IFC – TALI-8425-8424 COMM FOR RELAY ELR – TAM | 1A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||
| 17 | 13 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.012S02.PDF | 0238-008.012S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | GPS SAT CLOCK (SEL-2407) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 1.0 | 2A | S3_R2 | 3 | 2 | True | False | 2A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.066836 | 2 | True | 97.853 | FAIL | 1A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425-8424 COMM FOR RELAY ELR – TAM | 2A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||
| 18 | 14 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.016S01.PDF | 0238-008.016S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 115V & 24.9KV CT SUMMATION CABINETS | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 5.0 | 5A | S3_R2 | 3 | 2 | True | False | 5A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.084347 | 2 | True | 99.173 | PASS | 1A | 1994/12/15 | FIELD REVISIONS – GENERAL | 2A | 1996/01/12 | FIELD REVISIONS | 3 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 4B | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8424 RELAY RE | 4A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 5A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||
| 19 | 15 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.032S01.PDF | 0238-008.032S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 115/24.9KV UNIT #2 FRONT, PANEL #2 FRONT | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 14.0 | 14A | S3_R2 | 3 | 2 | True | False | 14A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.064506 | 2 | True | 97.682 | PASS | 10 | 1994/12/15 | FIELD REVISIONS – GENERAL | 11 | 1996/01/12 | FIELD REVISIONS | 12 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 13B | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8424 RELAY RE | 13A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 14A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||
| 20 | 16 | FAIL | FAIL | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.033S01.PDF | 0238-008.033S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 115KV UNIT #2 REAR | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 2.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.069757 | 2 | True | 98.109 | FAIL | 4 | 1994/12/15 | FIELD REVISIONS – GENERAL | 5 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 6C | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425-8424 COMM FOR RELAY ELR – TAM | 6B | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8424 RELAY RE | 6A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||
| 21 | 17 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.051S01.PDF | 0238-008.051S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | METERING AND RELAYING DIAGRAM | 24.9KV ONE LINE | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.077326 | 2 | True | 98.651 | PASS | 3 | 1993/07/30 | WAS DWG SO1, REVISED RELAYING | 4 | 2019/06/17 | FIELD REVISIONS – GENERAL | 5 | 219/06/17 A.0000506.067.003.002 CONVERTED TO MICROSTATION V8 FOR RECORD | 6B | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8424 RELAY RE | 6A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 22 | 18 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.053S01.PDF | 0238-008.053S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 24.9KV BUS A – THREE-LINE | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.088649 | 2 | True | 99.774 | PASS | 2 | 1989/10/30 | FIELD REVISIONS – GENERAL | 3 | 1993/07/30 | CONVERTED TO MICROSTATION V8 FOR RECORD | 4 | 1994/12/20 | FIELD REVISIONS – GENERAL | 5 | 1996/01/12 | FIELD REVISIONS | 6 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||
| 23 | 19 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.053S01-R.PDF | 0238-008.053S01-R | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | REMOVAL DRAWING – CONTROL | 24.9KV BUS A- THREE-LINE | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.090084 | 2 | True | 99.866 | PASS | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||||||
| 24 | 20 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.054S01.PDF | 0238-008.054S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | 24.9KV POTENTIALS & METERING | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.073975 | 2 | True | 98.445 | PASS | 3 | 1993/07/30 | WAS DWG SO1, REVISED RELAYING | 4 | 2019/06/1/7/ FIELD REVISIONS – GENERAL | 5 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 6B | 2023/05/31 | A.0000304.009.003.425 | IFC – TALI-8424 RELAY RE | 6A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 25 | 21 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.055S01.PDF | 0238-008.055S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | 24.9KV FEEDER– THREE LINE | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 5.0 | 5A | S3_R2 | 3 | 2 | True | False | 5A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.065573 | 2 | True | 97.741 | PASS | 1 | 1989/10/30 | FINAL REVISIONS PER WISCONSIN-UTE | 2 | 1993/07/30 | REVISE RELAING, ASSIGN PCS NUMBER | 3 | 1994/12/20 | FIELD REVISONS – GENERAL | 4 | 2023/05/31 | 5A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||||||||
| 26 | 22 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.055S02.PDF | 0238-008.055S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | 2.49KV FEEDER- THREE LINE | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 0.0 | 0A | S3_R2 | 3 | 2 | True | False | 0A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.06532 | 2 | True | 97.731 | PASS | 0A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||||||
| 27 | 23 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.056S01.PDF | 0238-008.056S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | UNDERFREQUENCY RELAYING | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 6.0 | 6A | S3_R2 | 3 | 2 | True | False | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.064842 | 2 | True | 97.688 | PASS | 4 | 1989/10/30 | FINAL REVISIONS PER WISCONSIN-UTE | 5 | 1993/07/30 | REVISED RELAYING, ASSIGN PSC NUMBER | 3 | 1994/12/20 | FIELD REVISIONS GENERAL | 4 | 1996/01/12 | FIELD REVISONS | 5 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 28 | 24 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.057S01.PDF | 0238-008.057S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | TRANSFORMER #1 DIFFERENTIAL & BACKUP | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.078478 | 2 | True | 98.845 | PASS | 4 | 1994/12/20 | FIELD REVISONS – GENERAL | 5 | 1996/01/12 | FIELD REVISIONS | 3 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 4 | 2026/07/06 | A.0000304.009.003.425 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8424 RELAY REPLACEMENT – SVS-CMT | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | ||||
| 29 | 25 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.063S01.PDF | 0238-008.063S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | 24.9KV AV461A CONTROL | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.087355 | 2 | True | 99.654 | PASS | 3 | 1989/10/30 | FINAL REVISIONS PER WI UTE | 4 | 1993/07/30 | REVISE RELAYING, ASSIGN PCS NUMBER | 5 | 1994/12/20 | FIELD REVISIONS – GENERAL | 6 | 1996/01/12 | FIELD REVISIONS | 7 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 30 | 26 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0283-008.063S01-R.PDF | 0283-008.063S01-R | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | REMOVAL DRAWING – CONTROL | 24.9KV AV461A CONTROL | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.083132 | 2 | True | 99.008 | PASS | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||||||
| 31 | 27 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.070S02.PDF | 0238-008.070S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 24.9KV OCB”S – AVA451A, AV461A & AV411B | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 6.0 | 6A | S3_R2 | 3 | 2 | True | False | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.070693 | 2 | True | 98.145 | PASS | 1 | 1989/10/30 | FINAL REVISIONS PER WI UTE | 2 | 1993/07/30 | REVISE RELAYING, ASSIGN PCS NUMBER | 3 | 1994/12/20 | FIELD REVISIONS – GENERAL | 4 | 1996/01/12 | FIELD REVISIONS | 5 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 32 | 28 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.070S02-R.PDF | 0238-008.070S02-R | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | REMOVAL DRAWING – CONTROL | WIRING DIAGRAM – 24.9KV OCB’S – AV451A, AV461A & AV411B | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 6.0 | 6A | S3_R2 | 3 | 2 | True | False | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.070675 | 2 | True | 98.143 | PASS | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||||||
| 33 | 29 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.086S01.PDF | 0238-008.086S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 24.9KV UNIT #3 FRONT | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.090389 | 2 | True | 99.605 | PASS | 3 | 1989/10/30 | FINAL REVISIONS PER WI UTE | 4 | 1993/07/30 | REVISE RELAYING, ASSIGN PCS NUMBER | 5 | 1994/12/20 | FIELD REVISIONS – GENERAL | 6 | 1996/01/12 | FIELD REVISIONS | 7 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 34 | 30 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.086S01-R.PDF | 0238-008.086S01-R | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | REMOVAL DRAWING – CONTROL | WIRING DIAGRAM – 24.9KV UNIT #3 FRONT | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.088815 | 2 | True | 99.524 | PASS | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||||||
| 35 | 31 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.086S02.PDF | 0238-008.086S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 24.9KV UNIT #3 FRONT SWING PANEL | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 8.0 | 8A | S3_R2 | 3 | 2 | True | False | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.065694 | 2 | True | 97.751 | PASS | 3 | 1989/10/30 | FINAL REVISIONS PER WI UTE | 4 | 1993/07/30 | REVISE RELAYING, ASSIGN PCS NUMBER | 5 | 1994/12/20 | FIELD REVISIONS – GENERAL | 6 | 1996/01/12 | FIELD REVISIONS | 7 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 8A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 36 | 32 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.087S01.PDF | 0238-008.087S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | 24.9KV UNIT #3 REAR | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 6.0 | 6A | S3_R2 | 3 | 2 | True | False | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.064268 | 2 | True | 97.693 | PASS | 1 | 1988/01/09 | PER FABRICATORS REVISIONS | 2 | 1989/10/30 | FINAL REVISIONS PER WI UTE | 3 | 1993/07/30 | REVISE RELAYING, ASSIGN PCS NUMBER | 4 | 1994/12/21 | FIELD REVISIONS – GENERAL | 5 | 2019/06/17 | A.0000506.067.003.002 | CONVERTED TO MICROSTATION V8 FOR RECORD | 6A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||
| 37 | 33 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.090S01.PDF | 0238-008.090S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | E1-PAC01 (2440) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 1.0 | 1A | S3_R2 | 3 | 2 | True | False | 1A | 2026/04/24 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.074074 | 2 | True | 98.425 | PASS | 0A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 1A | 2026/04/24 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||
| 38 | 34 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.091S02.PDF | 0238-008.091S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | SYNCHRONIZING & SUPERVISORY TERM PANEL (BOTTOM-HALF) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 7.0 | 7A | S3_R2 | 3 | 2 | True | False | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.069781 | 2 | True | 98.154 | PASS | 6D | 2023/05/31 | A.0000304.009.003.425 | IFR – SFE-TALI-INST TRANSGARD ELECTRIC FENCE | 6A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425 RELAY REPLACEMENT – SVS-CMT | 7A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||
| 39 | 35 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.092S02.PDF | 0238-008.092S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | SCHEMATIC DIAGRAM | PANEL LCU, E1-PAC01 (6F) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 4.0 | 4A | S3_R2 | 3 | 2 | True | False | 4A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.087062 | 2 | True | 99.634 | PASS | 1 | 1996/01/12 | FIELD REVISIONS | 2 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 3C | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8425-8424 COMM FOR RELAY ELR-TAM | 4A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||
| 40 | 36 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.093S01.PDF | 0238-008.093S01 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | CONNECTION – SUPERVISORY ANALOG INPUTS (FRONT OF RTU) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 3.0 | 3A | S3_R2 | 3 | 2 | True | False | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.090778 | 2 | True | 99.773 | PASS | 1 | 1995/06/06 | INSTALL WEATHER STATION | 2 | 2019/06/17 | CONVERTED TO MICROSTATION V8 FOR RECORD | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REPL BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||
| 41 | 37 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.093S02.PDF | 0238-008.093S02 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | CONNECTION WESTRONIC D20 RTU STATUS INPUTS (FRONT) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 3.0 | 3A | S3_R2 | 3 | 2 | True | False | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.066669 | 2 | True | 97.776 | PASS | 2D | 2023/05/31 | A.0000506.067.003.002 | IFR – SFE-TALI-INST TRANSGARD ELECTRIC FENCE | 2B | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8424 RELAY REPLACEMENT – SVS-CMT | 2A | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8424 RELAY REPLACEMENT – SVS-CMT | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||
| 42 | 38 | PASS | PASS | N/A | No black delta history detected on this page. | selected_binder.pdf | 0238-008.093S04.PDF | 0238-008.093S04 | TALIESIN SUBSTATION | TALIESIN SUBSTATION | TALI | WIRING DIAGRAM | CONNECTION WESTRONIC D20 RTU CAB CONTROL OUTPUTS (REAR) | NONE | CONSTRUCTION | IFC | ENGINEERING_DRAWING | THIS MAP/DOCUMENT IS A TOOL TO ASSIST EMPLOYEES IN THE PERFORMANCE OF THEIR JOBS, YOUR PERSONAL SAFETY IS PROVIDED FOR BY USING SAFETY PRACTICES, PROCEDURES AND EQUIPMENT AS DESCRIBED IN THE SAFETY TRAINING PROGRAMS, MANUALS AND SPARS | INTERNAL INFORMATION: DO NOT COPY OR DISTRIBUTE WITHOUT THE EXPRESS WRITTEN CONSENT FROM ARCLUME ENERGY | 3.0 | 3A | S3_R2 | 3 | 2 | True | False | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | OK | PASS | PASS | PASS | PASS | PASS | PASS | COMPACT_TITLEBLOCK | 0.087526 | 2 | True | 99.51 | PASS | 2C | 2023/05/31 | A.0000506.067.003.002 | IFC – TALI-8424-8424 COMM FOR RELAY ELR-TAM | 3A | 2026/07/06 | A.0000304.009.003.425 | IFC – SFE – TALI – REP BREAKER AV461A | PASS | IFC | ISSUED FOR CONSTRUCTION | coversheet.SPONSOR_ISSUED_FOR_RAW | IFC | PASS | Current revision description begins IFC, matching master IFC. | |||||||||||||||||
Coversheet Review
42 worksheet rows · 6 columns
| 1 | Coversheet Review | |||||
|---|---|---|---|---|---|---|
| 2 | Coversheet pass/fail checks and extracted project metadata. | |||||
| 3 | ||||||
| 4 | Section | Check | Status | Observed / Value | Expected | Reason |
| 5 | Overall | Overall Coversheet Status | PASS | PASS | All required checks passed | |
| 6 | Pass / Fail Checks | WBS4 Revision Present | PASS | PASS | PASS | |
| 7 | Pass / Fail Checks | WBS4 Date Present | PASS | PASS | PASS | |
| 8 | Pass / Fail Checks | WBS4 Code Present | PASS | PASS | PASS | |
| 9 | Pass / Fail Checks | WBS4 Description Present | PASS | PASS | PASS | |
| 10 | Pass / Fail Checks | Sheet Revision Match | PASS | |||
| 11 | Pass / Fail Checks | Project REV Letter Match | PASS | |||
| 12 | Pass / Fail Checks | WBS4 Code Match | PASS | |||
| 13 | Pass / Fail Checks | Project Description Match | PASS | |||
| 14 | Pass / Fail Checks | Logo Match | PASS | PASS | PASS | |
| 15 | Pass / Fail Checks | Drawing Number Match | PASS | PASS | PASS | |
| 16 | Pass / Fail Checks | Issued For Match | PASS | PASS | PASS | |
| 17 | Pass / Fail Checks | Asset Name Match | PASS | PASS | PASS | |
| 18 | Extracted Fields | Project Revision | A | |||
| 19 | Extracted Fields | WBS Level 4 | A.0000304.009.003.425 | |||
| 20 | Extracted Fields | Project Description | IFC – SFE – TALI – REPL BATTERY AND CHARGER | |||
| 21 | Extracted Fields | Drawing Number | 0238-000.002S01 | |||
| 22 | Extracted Fields | Drawing Name | ||||
| 23 | Extracted Fields | Print Date | 7/21/2026 | |||
| 24 | Extracted Fields | Drawing Date/Time | 7/21/2026 10:41:33 AM | |||
| 25 | Extracted Fields | Current Row REV | 2A | |||
| 26 | Extracted Fields | Current Row Date | 2026/07/06 | |||
| 27 | Extracted Fields | Current Row WBS4 | A.0000304.009.003.426 | |||
| 28 | Extracted Fields | Current Row Revision Description | IFC – SFE – TALI – REPL BREAKER AV461A | |||
| 29 | Extracted Fields | Sheet REV | 1 | |||
| 30 | Extracted Fields | Project REV Letter | ||||
| 31 | Extracted Fields | Logo Similarity | 0.794 | |||
| 32 | Extracted Fields | Sponsor Issued For | CONSTRUCTION | |||
| 33 | Extracted Fields | Title Block Issued For | CONSTRUCTION | |||
| 34 | Extracted Fields | Sponsor Asset Name | TALIESIN SUBSTATION | |||
| 35 | Extracted Fields | Title Block Asset Name | TALIESIN SUBSTATION | |||
| 36 | Extracted Fields | Substation Address | 5607 CO HWY C SPRING GREEN, WI 53588 | |||
| 37 | Extracted Fields | Telephone Number | (608) 588-7900 | |||
| 38 | Extracted Fields | Substation GPS | ||||
| 39 | Extracted Fields | Map Label Top | TALIESIN SUBSTATION | |||
| 40 | Extracted Fields | Map Label Bottom | TALIESIN SUBSTATION | |||
| 41 | Extracted Fields | Failed Checks | ||||
| 42 | Extracted Fields | Fail Reason Count | 0 | |||
Check Guide
10 worksheet rows · 4 columns
| 1 | Check Guide | |||
|---|---|---|---|---|
| 2 | Plain-English definition of visible report checks. | |||
| 3 | ||||
| 4 | Check Area | What It Means | Pass / Fail Logic | What the Reviewer Does |
| 5 | Delta / Cloud Relationship | Evaluates physical contact between a revision delta and its associated measured cloud. | Missing required geometry, separation beyond tolerance, or an unproven legacy gap is FAIL. Unqualified contact for recovered native geometry is REVIEW. Qualified native bounds may establish PASS within the configured tolerance; a positive accepted gap is not literal touching. | Correct confirmed FAIL findings. For REVIEW, inspect native geometry and obtain a qualified contact measurement. |
| 6 | Delta Symbol | Checks delta size, lineweight, text, color, and revision reference behavior. | Operational may tolerate selected strict-reference geometry deviations; required checks still fail. | Correct symbol size/lineweight/text where required by project profile. |
| 7 | Revision Cloud | Checks cloud geometry, ridge/radius, and cloud coverage around changed content. | Strict findings may be accepted operationally if profile allows them. | Review whether profile tolerance should be hardened. |
| 8 | Green Removal Hatching | Checks green removal hatch line presence, spacing, and lineweight. | Required hatch integrity failures are selected operational FAIL rows. | Add missing hatch lines or correct spacing/lineweight. |
| 9 | Title Block | Checks sheet metadata, REV/WBS rows, seal/logo/warning/internal text, and page status. | Page-level extraction must pass configured title block requirements. | Correct title block metadata or revision history rows. |
| 10 | Coversheet | Checks coversheet project identity, WBS row, logo, issued-for, asset, map/contact fields. | Coversheet overall should pass before issuing binder. | Correct coversheet metadata and current revision row. |
Report QA
19 worksheet rows · 4 columns
| 1 | Report QA | |||
|---|---|---|---|---|
| 2 | Internal report-build verification. Hidden by default in the client-facing workbook. | |||
| 3 | ||||
| 4 | QA Check | Status | Result | Verification Basis |
| 5 | Required source files present | PASS | All required source files were available to build the client report. | Report build verification |
| 6 | Actionable issue count | PASS | 237 | Selected operational result = FAIL |
| 7 | Accepted by Operational count | PASS | 164 | Strict-reference findings accepted by the selected operational profile |
| 8 | Delta/cloud touch failures | PASS | 43 | Hard-touch relationship audit |
| 9 | Visual previews embedded | PASS | 307 | Issue-level evidence previews when available |
| 10 | Visual preview support | PASS | Image support available | Workbook image embedding check |
| 11 | Client workbook structure | PASS | Required client-facing sheets were created. | Report build verification |
| 12 | Title Block Review retained | PASS | 38 | Page-level title block data retained in the visible report |
| 13 | Coversheet Review retained | PASS | 1 | Coversheet checks retained in the visible report |
| 14 | Page Summary issue counts | PASS | Actionable Issue Count uses selected operational failures directly. | Issue Detail / Page Summary alignment |
| 15 | Accepted operational summary | PASS | Strict-reference findings accepted by operational profile are summarized separately. | Page Summary clarity check |
| 16 | Title block status logic | PASS | Title Block status combines extraction status and revision-history checks. | Title Block / Revision History alignment |
| 17 | Advisory / Design Review count | PASS | 70 | Selected REVIEW or selected PASS with strict/operational REVIEW |
| 18 | Visual evidence binding gate | PASS | 471 | Every visible row has issue-specific evidence |
| 19 | Cross-toolkit page fallback | PASS | Disabled | Evidence is never borrowed from another toolkit on the same page |
Run Details
17 worksheet rows · 3 columns
| 1 | Run Details | ||
|---|---|---|---|
| 2 | Run metadata and report-generation details. | ||
| 3 | |||
| 4 | Field | Value | Notes |
| 5 | Project Root | C:\Users\Marc Smith\Documents\Codex\2026-09-07\i-want-you-to-review-my\validation_measurement_projects\binder_jobs\job_bee35076a066\tools | |
| 6 | Master Folder | 99_master | |
| 7 | Division | PSCO | |
| 8 | Subdivision | SFE | |
| 9 | Issued For | IFC | |
| 10 | Policy Mode | Operational_Accepted | |
| 11 | First Source Update | 2026-09-14 17:55:31 | File timestamp only; not an execution receipt |
| 12 | Last Source Update | 2026-09-14 17:59:00 | File timestamp only; not an execution receipt |
| 13 | Source Time Span | 3m 29s | From earliest/latest consumed source timestamp |
| 14 | Legacy Workbook | Merged_Final_Report.xlsx | kept as technical audit workbook |
| 15 | Client Workbook | SVS_Client_Validation_Report.xlsx | generated clean report |
| 16 | Annotated Delta/Cloud PDF | Visual_Evidence/Delta_Cloud_Annotated.pdf | |
| 17 | Annotated Coversheet PDF | Visual_Evidence/Coversheet_Annotated.pdf | |
No matching rows. Clear the search to see the full sheet.
Original worksheet values and embedded previews. Evidence-file buttons jump to the matching workbook preview when available. PDF filenames are retained as references; the source PDFs are not included in this web view.
Review capacity & business value
Put your review effort
into perspective.
Explore the potential value of reducing repetitive checking. Keep machine runtime separate from human work, and include the review obligations your process still requires.
Both figures follow the assumptions below. They are planning scenarios, not measured SVS performance or a customer savings claim.
Illustrative planning output
Model a focused review workflow.
- Current human review / binder
- 3.00 h
- Unattended runtime / binder
- 4.0 min
- Finding review & closeout / binder
- 17.0 min
- Other required review / binder
- 15.0 min
- Total human review after checking
- 32.0 min
- Net time recovered / binder
- 1.85 h
- Net time recovered / year
- 6,660 h
- Annual net time value
- $999,000
- FTE-equivalent capacity change
- 4.57 FTE
- Investment recovery illustration
- No investment entered
Capacity is time that could be reassigned, not an automatic reduction in payroll or a prediction of profit.
How this model works
Current human hours = pages × manual minutes per page ÷ 60 + manual setup/closeout ÷ 60.
Human hours after checking = (pages × finding-page percentage × review minutes per finding page + launch/closeout + other required review) ÷ 60.
Machine runtime = pages × entered seconds per page ÷ 60. Add attended processing to other required human review if your process requires it.
Potential net hours = current human hours − human hours after checking + entered rework hours × entered rework reduction.
Realized net hours = positive potential net hours × realization percentage. Negative results are retained in full to show added work.
Annual time value = realized net hours × binders per month × 12 × loaded hourly rate. FTE equivalent divides annual hours by the entered productive hours. Investment recovery divides the optional one-time investment by positive monthly time value.
The default adds 15 minutes of other required review to the older page’s example. This is an editable allowance, not a tested requirement. Include uncovered checks, uncertain or missed findings, client sampling, and attended runtime where applicable. The model excludes recurring software, deployment, and operating costs; it is a labor-time illustration, not net ROI.
A representative pilot measures actual review effort, coverage, incorrect or missed findings, processing time, and adoption. The default 6 seconds per page and all other inputs are illustrative assumptions. A PASS on supported checks does not remove uncovered review obligations.
Strategic fit for AEC software companies
A focused answer to
a costly review bottleneck.
For Autodesk, Bluebeam and other AEC product teams: evaluate working drawing-standards IP, real outputs and a defined path to broader commercial qualification.
Put routine checks into software.
Coversheet, title-block and revision-presentation checks address work that otherwise requires repeated visual searching, comparison and documentation.
Make the next decision easier.
Bring findings, observed values, expected criteria and drawing previews together. Measure the reduction in human review effort during an agreed pilot.
Assess the implementation and its fit.
Review the existing checking engines, client profiles, reporting workflow and development priorities through an SVS-operated technical evaluation.
The calculator models potential operating value; it does not set the IP purchase price. Acquisition scope, integration work and commercial terms are evaluated separately.
Familiar tools. Clear responsibilities.
The client owns the standard.
Your team owns the decision.
SVS supplies supported observations and evidence. Designers still edit the source drawings, and the client’s process determines who reviews and accepts the work.
Designers & drafting teams
Investigate findings, update the drawing in the normal authoring tool, and submit a revised PDF for the applicable checks.
Client-authorized reviewers
Confirm rule applicability, resolve exceptions, and determine acceptance. The role may be a designer, checker, utility QA reviewer, or engineer.
Client standards owners
Define the requirements, permitted exceptions, approved handling, and release process. Evaluate supported coverage against representative cases.
Also reviewing the requested change?
SVS Redline follows engineering intent into the returned drawing. It is a separate product with a complementary review task.
Explore the Redline Platform ↗Planned development
Extend the working
platform’s value.
Build on the original platform through targeted repairs, client qualification and maintainable delivery.
De-identified support packages
Prepare drawing and report evidence for support with configured project identifiers removed and useful context retained. The original export route is being repaired and qualified; support export remains disabled in the current evaluation build.
Confirm the rules and expected outcomes.
Use the client rule register and representative cases to qualify applicable requirements, remaining seal/hatch work and broader cloud representations.
Maintain the three core checking areas.
Consolidate accumulated patches around coversheets, title blocks and deltas/clouding while retaining the original checking behavior and evidence.
Develop a fuller review record.
Extend the finding-to-correction record and evaluate controlled source-correction workflows, PDF re-export and independent re-verification.
Before the pilot
A few direct answers.
What is available for evaluation today?
The repaired original desktop workflow runs implemented PDF checks and produces client/technical reports and annotated evidence. Completed development work also includes separate run snapshots, explicit incomplete states, evidence consistency controls, and scoped native cloud contact/color measurements. The demonstrated functions are suitable for a controlled designer/client pilot; wider coverage and deployment qualification remain in progress.
Will it check every requirement in our standards?
Coverage depends on the implemented rule, supported profile, and PDF representation. A profile proposal alone does not create qualified checks. Client-rule mapping, broader cloud representations, and selected hatch and seal checks still require work. A pilot identifies what SVS can assess and what stays with the existing review process.
Do reviewers only look at flagged pages?
The report is a useful starting point for findings and unresolved questions. Reviewers also need to address uncovered requirements and the client’s sampling or acceptance policy. A clean result on supported checks is not proof that the entire drawing is correct.
Can we keep our current CAD and PDF tools?
Yes. The current workflow receives PDFs from the team’s normal authoring environment. Native DGN/DWG/BIM inspection, automatic source-drawing correction, and direct Autodesk or Bluebeam integrations are outside the demonstrated current scope. Controlled source correction and re-verification remain a development direction.
Does the binder need to be uploaded to a public cloud?
The demonstrated workflow runs locally. Installation, access, dependencies, permitted disclosure, and client environment requirements are part of deployment evaluation. Broad enterprise or VDI qualification has not been completed.
What happened to Secure Binder Support?
The older page and walkthrough describe legacy support-package tooling. Export is disabled in the current supported evaluation build. It should not be treated as an available qualified de-identification or sharing capability; the client’s classification and disclosure rules continue to apply.
Does Standards Platform approve or release a drawing?
No. It reports supported check results. Client drafting acceptance, engineering judgment where required, and document release remain with the organization’s authorized people and processes.
From demonstration to measured pilot
Bring your standards.
See what the evidence says.
Start with a private walkthrough. Compare the supported checks with your client’s requirements, agree on representative examples, and measure the review value with your team.
Standard Validation Systems Corporation · Current development scope is available for controlled technical evaluation. Client acceptance and document-release authority remain separate from software observations.